Nelineární ultrazvuková pseudo-tomografie s časově reversními zrcadly
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F08%3A00317520" target="_blank" >RIV/61388998:_____/08:00317520 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nonlinear Time Reversal Ultrasonic Pseudo-Tomography
Popis výsledku v původním jazyce
Nonlinear Elastic Wave Spectroscopy (NEWS) becomes new effective method for non-destructive testing of complex structures providing high sensitivity of damage detection. One of the most promising NEWS procedures is Nonlinear Time Reversal Acoustics (NLTRA) realizable in a lot of different ways. Common NLTRA procedure is mostly global, which means that localization of defect by this procedure can be often difficult. A modification of NLTRA is proposed in this paper, based on similar arrangement as ultrasonic tomography. Computer controlled switching between transmitting and receiving transducers is realized by specially designed high-voltage relay multiplexer. The matrix of reconstructed and back-received signals and their spectra is then analyzed, andnonlinear features like higher harmonics etc. are examined on all wave-paths. Cross-section of different wave-paths with the highest nonlinear features allocates a sector of probable defect occurrence.
Název v anglickém jazyce
Nonlinear Time Reversal Ultrasonic Pseudo-Tomography
Popis výsledku anglicky
Nonlinear Elastic Wave Spectroscopy (NEWS) becomes new effective method for non-destructive testing of complex structures providing high sensitivity of damage detection. One of the most promising NEWS procedures is Nonlinear Time Reversal Acoustics (NLTRA) realizable in a lot of different ways. Common NLTRA procedure is mostly global, which means that localization of defect by this procedure can be often difficult. A modification of NLTRA is proposed in this paper, based on similar arrangement as ultrasonic tomography. Computer controlled switching between transmitting and receiving transducers is realized by specially designed high-voltage relay multiplexer. The matrix of reconstructed and back-received signals and their spectra is then analyzed, andnonlinear features like higher harmonics etc. are examined on all wave-paths. Cross-section of different wave-paths with the highest nonlinear features allocates a sector of probable defect occurrence.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BI - Akustika a kmity
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
1st International Symposium on Laser Ultrasonics: Science, technology and Applications
ISSN
1435-4934
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
14
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—