Influence of Circuit Parameters on Operating Regions of PWM Rectifier under Unbalanced Voltage Supply
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F09%3A00327223" target="_blank" >RIV/61388998:_____/09:00327223 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Circuit Parameters on Operating Regions of PWM Rectifier under Unbalanced Voltage Supply
Popis výsledku v původním jazyce
Electric drives may be negatively affected by non-standard conditions in the power network such as voltage unbalance, which may arise in three-phase power networks. The unbalance can be caused by a failure in the network or by unbalanced load in the vicinity of the affected drive. Unsymmetrical voltages at the input of a voltage source inverter cause pulsations in the DC link voltage when not properly taken care of. This may result in reduced power capabilities of the drive. The paper deals with the methods to address this problem and with the limitations placed on the drive when operated from the unbalanced voltage supply. Influence of circuit parameters on the operating regions and their constraints are particularly dealt with.
Název v anglickém jazyce
Influence of Circuit Parameters on Operating Regions of PWM Rectifier under Unbalanced Voltage Supply
Popis výsledku anglicky
Electric drives may be negatively affected by non-standard conditions in the power network such as voltage unbalance, which may arise in three-phase power networks. The unbalance can be caused by a failure in the network or by unbalanced load in the vicinity of the affected drive. Unsymmetrical voltages at the input of a voltage source inverter cause pulsations in the DC link voltage when not properly taken care of. This may result in reduced power capabilities of the drive. The paper deals with the methods to address this problem and with the limitations placed on the drive when operated from the unbalanced voltage supply. Influence of circuit parameters on the operating regions and their constraints are particularly dealt with.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F1273" target="_blank" >GA102/09/1273: Vliv změn napětí ve stejnosměrném meziobvodu napěťového měniče na chod elektrického pohonu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE International Electric Machines and Drives Conference - IEMDC 2009
ISBN
978-1-4244-4252-2
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Miami - Florida
Místo konání akce
Miami - Florida
Datum konání akce
3. 5. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—