Nonlinear elastic wave spectroscopy in symbiosis with time reversal for localization of defects: TR-NEWS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F09%3A00334347" target="_blank" >RIV/61388998:_____/09:00334347 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nonlinear elastic wave spectroscopy in symbiosis with time reversal for localization of defects: TR-NEWS
Popis výsledku v původním jazyce
Using the symmetry invariance and reciprocity the classical NEWS methods are supplemented and improved by practically elaborated TR-NEWS procedure having the intrinsic property of enlarging frequency analysis bandwidth. Coded excitations have been generalized using Symmetry Analysis ESAM (Excitation Symmetry Analysis Method), including also the chirp-coded excitation, which improves the signal to noise ratio and enables harmonic imaging of complex specimen. In this paper, we propose a new NDT application of the above approaches implemented on a composite specimen with adhesive joints. The calibrated chirp-coded TR-NEWS imaging of the sample is obtained by using the symmetrical excitations, and pre- and post- signal processing. Localization of the scatterer is illustrated on 2D plot.
Název v anglickém jazyce
Nonlinear elastic wave spectroscopy in symbiosis with time reversal for localization of defects: TR-NEWS
Popis výsledku anglicky
Using the symmetry invariance and reciprocity the classical NEWS methods are supplemented and improved by practically elaborated TR-NEWS procedure having the intrinsic property of enlarging frequency analysis bandwidth. Coded excitations have been generalized using Symmetry Analysis ESAM (Excitation Symmetry Analysis Method), including also the chirp-coded excitation, which improves the signal to noise ratio and enables harmonic imaging of complex specimen. In this paper, we propose a new NDT application of the above approaches implemented on a composite specimen with adhesive joints. The calibrated chirp-coded TR-NEWS imaging of the sample is obtained by using the symmetrical excitations, and pre- and post- signal processing. Localization of the scatterer is illustrated on 2D plot.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BI - Akustika a kmity
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
NDT in PROGRESS
ISBN
978-80-214-3968-9
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
University of Technology Brno
Místo vydání
Brno
Místo konání akce
Praha
Datum konání akce
12. 10. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—