Identification of the Temperature Field in Pulsatile Impinging Flow
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F10%3A00354200" target="_blank" >RIV/61388998:_____/10:00354200 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24210/10:#0001661
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Identification of the Temperature Field in Pulsatile Impinging Flow
Popis výsledku v původním jazyce
The presented paper shows the possibility of using holographic interferometry and hot-wire anemometry in the research of heat transfer from impingement pulsatile flow. All these methods have a response time too long for measuring instant values of the heat transfer coefficient on a surface cooled/heated by impingement pulsatile flow. This shortcoming should be overcome by using CTA glue-on probes or, preferably, by using optical methods such as holographic interferometry. It is necessary to employ a special holographic setup with double sensitivity instead of the commonly used Mach-Zehnder type of holographic interferometer in order to attain the parameters sufficient for the studied case. The results from the holographic interferometry experiments will be compared with the temperature field achieved by methods of hot-wire anemometry.
Název v anglickém jazyce
Identification of the Temperature Field in Pulsatile Impinging Flow
Popis výsledku anglicky
The presented paper shows the possibility of using holographic interferometry and hot-wire anemometry in the research of heat transfer from impingement pulsatile flow. All these methods have a response time too long for measuring instant values of the heat transfer coefficient on a surface cooled/heated by impingement pulsatile flow. This shortcoming should be overcome by using CTA glue-on probes or, preferably, by using optical methods such as holographic interferometry. It is necessary to employ a special holographic setup with double sensitivity instead of the commonly used Mach-Zehnder type of holographic interferometer in order to attain the parameters sufficient for the studied case. The results from the holographic interferometry experiments will be compared with the temperature field achieved by methods of hot-wire anemometry.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA200760801" target="_blank" >IAA200760801: Pulzující proudy pro řízení proudových polí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Numerical Analysis and Applied Mathematics
ISBN
978-0-7354-0834-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
American Institute of Physics
Místo vydání
Melville
Místo konání akce
Rhodos
Datum konání akce
19. 9. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—