Control of Active Front-End Rectifier under Unbalanced Voltage Supply and DC-Link Pulsations
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F11%3A00364181" target="_blank" >RIV/61388998:_____/11:00364181 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5994868" target="_blank" >http://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=5994868</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IEMDC.2011.5994868" target="_blank" >10.1109/IEMDC.2011.5994868</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Control of Active Front-End Rectifier under Unbalanced Voltage Supply and DC-Link Pulsations
Popis výsledku v původním jazyce
Voltage pulsations in the DC bus may develop if the voltage-source inverter is fed from an unbalanced voltage supply. Negative effects on the connected electric machine and on the power grid usually result from such operation. It is possible to entirelyeliminate or at least minimize such negative effects by suitable control of the active front end of the inverter. The control range of the active front end rectifier is reduced in such a mode of operation. Suitable control method for eliminating the voltage pulsations in the DC bus is discussed in the paper and operation in case of various types of unbalance is simulated and investigated.
Název v anglickém jazyce
Control of Active Front-End Rectifier under Unbalanced Voltage Supply and DC-Link Pulsations
Popis výsledku anglicky
Voltage pulsations in the DC bus may develop if the voltage-source inverter is fed from an unbalanced voltage supply. Negative effects on the connected electric machine and on the power grid usually result from such operation. It is possible to entirelyeliminate or at least minimize such negative effects by suitable control of the active front end of the inverter. The control range of the active front end rectifier is reduced in such a mode of operation. Suitable control method for eliminating the voltage pulsations in the DC bus is discussed in the paper and operation in case of various types of unbalance is simulated and investigated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F09%2F1273" target="_blank" >GA102/09/1273: Vliv změn napětí ve stejnosměrném meziobvodu napěťového měniče na chod elektrického pohonu</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Electric Machines and Drives Conference (IEMDC 2011)
ISBN
978-1-4577-0060-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
324-329
Název nakladatele
IEEE
Místo vydání
Niagara Falls
Místo konání akce
Niagara Falls
Datum konání akce
15. 5. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—