EXPERIMENTAL APPARATUS FOR MEASUREMENT OF DENSITY OF SUPERCOOLED WATER AT HIGH PRESSURE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F11%3A00368096" target="_blank" >RIV/61388998:_____/11:00368096 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
EXPERIMENTAL APPARATUS FOR MEASUREMENT OF DENSITY OF SUPERCOOLED WATER AT HIGH PRESSURE
Popis výsledku v původním jazyce
Thermodynamic behavior of supercooled water (metastable fluid water existing transiently below the equilibrium freezing point) at high pressures was subject to many recent theoretical studies. Some of them assume that a second critical point of water exists, related to two liquid phases of supercooled water: the low-density liquid and the high-density liquid. To test these theories, an original experimental cryogenic apparatus is being developed. The volume changes are measured optically in custom-treated fused-silica capillary tubes. The capillaries are placed in a metal vessel designed for pressures up to 200 MPa. The vessel is connected to a circulation thermostat enabling a rapid change of temperature to prevent freezing. A new high-vacuum device was developed for degassing of the ultrapure water sample and filling it into the measuring capillaries. The experiments will contribute to fundamental understanding of the anomalous behavior of water and to applications in meteorology, ae
Název v anglickém jazyce
EXPERIMENTAL APPARATUS FOR MEASUREMENT OF DENSITY OF SUPERCOOLED WATER AT HIGH PRESSURE
Popis výsledku anglicky
Thermodynamic behavior of supercooled water (metastable fluid water existing transiently below the equilibrium freezing point) at high pressures was subject to many recent theoretical studies. Some of them assume that a second critical point of water exists, related to two liquid phases of supercooled water: the low-density liquid and the high-density liquid. To test these theories, an original experimental cryogenic apparatus is being developed. The volume changes are measured optically in custom-treated fused-silica capillary tubes. The capillaries are placed in a metal vessel designed for pressures up to 200 MPa. The vessel is connected to a circulation thermostat enabling a rapid change of temperature to prevent freezing. A new high-vacuum device was developed for degassing of the ultrapure water sample and filling it into the measuring capillaries. The experiments will contribute to fundamental understanding of the anomalous behavior of water and to applications in meteorology, ae
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
International Conference Experimental Fluid Mechanics 2011
ISBN
978-80-7372-784-0
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
680-687
Název nakladatele
TU Liberec
Místo vydání
Liberec
Místo konání akce
Jičín
Datum konání akce
22. 11. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—