AN ANNULAR IMPINGING JET ALTERNATED BY PULSE-MODULATED SYNTHETIC JETS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F11%3A00439991" target="_blank" >RIV/61388998:_____/11:00439991 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
AN ANNULAR IMPINGING JET ALTERNATED BY PULSE-MODULATED SYNTHETIC JETS
Popis výsledku v původním jazyce
The present experimental study focuses on a generation and control of annular impinging jets. The used working fluid is air An active flow control system is designed with six radial synthetic jets, which are generated by a common actuator located in thecentral body of the annular nozzle. The synthetic jets are pulse-modulated. Flow visualization and measurements of the wall pressure and wall heat transfer have been performed. Two flowfield steady patterns A and B (small or large recirculation bubbles,respectively) are recognized. The pattern B exists without the actuation, the unmodulated actuation causes the flowfield switching into the pattern A, and the pulse-modulated actuation generates an alternating flowfield. The present results indicate thatthe area of higher heat transfer can be slightly spread by means of flow alternation. However, the penalty for this slight gain is a substantial reduction of the heat transfer in the central area.
Název v anglickém jazyce
AN ANNULAR IMPINGING JET ALTERNATED BY PULSE-MODULATED SYNTHETIC JETS
Popis výsledku anglicky
The present experimental study focuses on a generation and control of annular impinging jets. The used working fluid is air An active flow control system is designed with six radial synthetic jets, which are generated by a common actuator located in thecentral body of the annular nozzle. The synthetic jets are pulse-modulated. Flow visualization and measurements of the wall pressure and wall heat transfer have been performed. Two flowfield steady patterns A and B (small or large recirculation bubbles,respectively) are recognized. The pattern B exists without the actuation, the unmodulated actuation causes the flowfield switching into the pattern A, and the pulse-modulated actuation generates an alternating flowfield. The present results indicate thatthe area of higher heat transfer can be slightly spread by means of flow alternation. However, the penalty for this slight gain is a substantial reduction of the heat transfer in the central area.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS OF THE ASME/JSME 8TH THERMAL ENGINEERING JOINT CONFERENCE 2011
ISBN
978-0-7918-5454-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
569-576
Název nakladatele
AMER. SOC. MECHANICAL ENGINEERS
Místo vydání
NEW YORK
Místo konání akce
Honolulu
Datum konání akce
13. 3. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000319843000068