Energy dissipated during the cavitation bubble collapse close to a solid wall
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F12%3A00388347" target="_blank" >RIV/61388998:_____/12:00388347 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/46747885:24210/12:#0002683
Výsledek na webu
<a href="http://dx.doi.org/10.3850/978-981-07-2826-7_259" target="_blank" >http://dx.doi.org/10.3850/978-981-07-2826-7_259</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3850/978-981-07-2826-7_259" target="_blank" >10.3850/978-981-07-2826-7_259</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Energy dissipated during the cavitation bubble collapse close to a solid wall
Popis výsledku v původním jazyce
The aim of this study is to determine the energy dissipated during cavitation bubble collapse close to a rigid wall for different bubble radii and distances of the bubble from the wall. The bubble is generated by electric spark and the total energy of collapse is calculated from the difference between the energy required to grow the bubble to its first radius and the same energy for the second maximal radius. Impact loads are determined using the PVDF film and documented with time-resolved photography.The response of the shock pressure is monitored in the far field using the PVDF needle hydrophone. The energy of the shockwave propagated from the bubble origin at collapse is estimated from the measured data for different standoff distances.
Název v anglickém jazyce
Energy dissipated during the cavitation bubble collapse close to a solid wall
Popis výsledku anglicky
The aim of this study is to determine the energy dissipated during cavitation bubble collapse close to a rigid wall for different bubble radii and distances of the bubble from the wall. The bubble is generated by electric spark and the total energy of collapse is calculated from the difference between the energy required to grow the bubble to its first radius and the same energy for the second maximal radius. Impact loads are determined using the PVDF film and documented with time-resolved photography.The response of the shock pressure is monitored in the far field using the PVDF needle hydrophone. The energy of the shockwave propagated from the bubble origin at collapse is estimated from the measured data for different standoff distances.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F10%2F1428" target="_blank" >GAP101/10/1428: Mechanizmy kolapsu a štěpení ultrazvukem buzených kavitačních bublin v blízkosti pevné stěny v Newtonské kapalině</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Eighth International Symposium on Cavitation (CAV 2012)
ISBN
978-981-07-2826-7
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
146-151
Název nakladatele
Research Publishing Services
Místo vydání
Singapore
Místo konání akce
Singapur
Datum konání akce
13. 8. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—