Design of an experimental apparatus for measurement of the surface tension of metastable fluids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F13%3A00392001" target="_blank" >RIV/61388998:_____/13:00392001 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/epjconf/20134501094" target="_blank" >http://dx.doi.org/10.1051/epjconf/20134501094</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20134501094" target="_blank" >10.1051/epjconf/20134501094</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design of an experimental apparatus for measurement of the surface tension of metastable fluids
Popis výsledku v původním jazyce
A unique experimental apparatus for measurement of the surface tension of aqueous mixtures has been designed, manufactured, and tested in our laboratory. Functionality of all main components of the apparatus, e.g., glass chamber with the capillary tube,temperature control unit consisting of two thermostatic baths with special valves for rapid temperature jumps, helium distribution setup allowing pressure variation above the liquid meniscus inside the capillary tube, has been successfully tested. Preliminary results for the surface tension of the stable and metastable supercooled water measured by the capillary elevation method at atmospheric pressure are provided. The surface tension of water measured at temperatures between +26 °C and ?11 °C is in good agreement with the extrapolated IAPWS correlation.
Název v anglickém jazyce
Design of an experimental apparatus for measurement of the surface tension of metastable fluids
Popis výsledku anglicky
A unique experimental apparatus for measurement of the surface tension of aqueous mixtures has been designed, manufactured, and tested in our laboratory. Functionality of all main components of the apparatus, e.g., glass chamber with the capillary tube,temperature control unit consisting of two thermostatic baths with special valves for rapid temperature jumps, helium distribution setup allowing pressure variation above the liquid meniscus inside the capillary tube, has been successfully tested. Preliminary results for the surface tension of the stable and metastable supercooled water measured by the capillary elevation method at atmospheric pressure are provided. The surface tension of water measured at temperatures between +26 °C and ?11 °C is in good agreement with the extrapolated IAPWS correlation.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EFM12 - EXPERIMENTAL FLUID MECHANICS 2012
ISBN
978-80-7372-912-7
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
Technical University of Liberec
Místo vydání
Liberec
Místo konání akce
Hradec Králové
Datum konání akce
20. 11. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000319932200094