Computational Modelling of the Shape Deviations of the Sphere Surfaces of Ceramic Heads of Hip Joint Replacement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F14%3A00423745" target="_blank" >RIV/61388998:_____/14:00423745 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26210/13:PU107214
Výsledek na webu
<a href="http://dx.doi.org/10.1007/978-3-319-00846-2_22" target="_blank" >http://dx.doi.org/10.1007/978-3-319-00846-2_22</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-00846-2_22" target="_blank" >10.1007/978-3-319-00846-2_22</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computational Modelling of the Shape Deviations of the Sphere Surfaces of Ceramic Heads of Hip Joint Replacement
Popis výsledku v původním jazyce
The problem of the damage of the bioimplants is very important today. In the endoprosthesis surgery there is a large percentage of implant defects, which cause the failure of the whole prosthesis. One kind of the total hip replacement functionality lossis acetabular cup pull-off from pelvis bone. This paper is aimed at manufacture perturbations (shape deviations) analysis as one of the possible reasons to this kind of failure. Dimension and of geometry manufacturing perturbations (roundness) were analyzed in detail. It was found, that these perturbations affect considered values of contact pressure and frictional moment. Contact pressure and frictional moment are quantities affecting replacement success and durability.
Název v anglickém jazyce
Computational Modelling of the Shape Deviations of the Sphere Surfaces of Ceramic Heads of Hip Joint Replacement
Popis výsledku anglicky
The problem of the damage of the bioimplants is very important today. In the endoprosthesis surgery there is a large percentage of implant defects, which cause the failure of the whole prosthesis. One kind of the total hip replacement functionality lossis acetabular cup pull-off from pelvis bone. This paper is aimed at manufacture perturbations (shape deviations) analysis as one of the possible reasons to this kind of failure. Dimension and of geometry manufacturing perturbations (roundness) were analyzed in detail. It was found, that these perturbations affect considered values of contact pressure and frictional moment. Contact pressure and frictional moment are quantities affecting replacement success and durability.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-34632S" target="_blank" >GA13-34632S: Zvýšení úrovně výpočtového modelování chování keramické hlavice totální kyčelní endoprotézy</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013
ISBN
978-3-319-00845-5
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
89-92
Název nakladatele
Springer
Místo vydání
Seville
Místo konání akce
Seville
Datum konání akce
25. 9. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—