In situ calibration of acoustic emission transducers by time reversal method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F16%3A00456674" target="_blank" >RIV/61388998:_____/16:00456674 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/16:00320616
Výsledek na webu
<a href="http://ac.els-cdn.com/S0924424716300334/1-s2.0-S0924424716300334-main.pdf?_tid=0acf4736-ef6d-11e5-b826-00000aacb362&acdnat=1458568911_1c21eda9762b905a684ff939463ef3fe" target="_blank" >http://ac.els-cdn.com/S0924424716300334/1-s2.0-S0924424716300334-main.pdf?_tid=0acf4736-ef6d-11e5-b826-00000aacb362&acdnat=1458568911_1c21eda9762b905a684ff939463ef3fe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.sna.2016.01.033" target="_blank" >10.1016/j.sna.2016.01.033</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In situ calibration of acoustic emission transducers by time reversal method
Popis výsledku v původním jazyce
Conventional methods of calibration of acoustic emission transducers require an already calibratedreference transducer and/or special test specimen. Moreover the calibration results are not directlytransferrable to practice, since they are dependent on bonding conditions and mechanical propertiesof the medium. In this paper a reference-free in situ calibration method is proposed. It is based on acombination of time reversed acoustics and reciprocal calibration and allows accurate determination oftransducers’ frequency responses. The method was developed and successfully experimentally verifiedassuming that frequency response of used transducers is the same for transmission and reception. Sub-sequently the analysis was extended considering irreversible transducers and applied to experimentaldata. Of five tested transducers, three were found reversible and two demonstrated resonance frequencyshift in lower frequency region between reception and transmission.
Název v anglickém jazyce
In situ calibration of acoustic emission transducers by time reversal method
Popis výsledku anglicky
Conventional methods of calibration of acoustic emission transducers require an already calibratedreference transducer and/or special test specimen. Moreover the calibration results are not directlytransferrable to practice, since they are dependent on bonding conditions and mechanical propertiesof the medium. In this paper a reference-free in situ calibration method is proposed. It is based on acombination of time reversed acoustics and reciprocal calibration and allows accurate determination oftransducers’ frequency responses. The method was developed and successfully experimentally verifiedassuming that frequency response of used transducers is the same for transmission and reception. Sub-sequently the analysis was extended considering irreversible transducers and applied to experimentaldata. Of five tested transducers, three were found reversible and two demonstrated resonance frequencyshift in lower frequency region between reception and transmission.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BI - Akustika a kmity
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators A - Physical
ISSN
0924-4247
e-ISSN
—
Svazek periodika
240
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
50-56
Kód UT WoS článku
000372693600007
EID výsledku v databázi Scopus
2-s2.0-84957585773