Resonance Tube or Lax Vox?
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F17%3A00469140" target="_blank" >RIV/61388998:_____/17:00469140 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jvoice.2016.10.024" target="_blank" >http://dx.doi.org/10.1016/j.jvoice.2016.10.024</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jvoice.2016.10.024" target="_blank" >10.1016/j.jvoice.2016.10.024</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Resonance Tube or Lax Vox?
Popis výsledku v původním jazyce
Objective. This study compares the flow resistance of Resonance tube (RT) and Lax Vox tube (LVT) when submerged 2 cm and 10 cm in water, as well as phonation into the tubes in these conditions.nMethods. In the in vitro experiment, the air pressure for flow rates of 60-600 mL/s was measured at the tube inlet, when the outer end of the tube was submerged 2 cm and 10 cm below water surface in 30 degrees, 45 degrees, and 90 degrees angle. In the in vivo experiment, 14 subjects phonated in habitual loudness and loudly into both tubes, with the outer end 2 cm and 10 cm in water. RT was immersed in a 45 degrees angle and LVT in a 90 degrees angle in water. Oral pressure, contact quotient from electroglottographic signal, and sound pressure level were studied. Sensations during phonation were reported in an interview.nResults. Flow resistance was slightly lower with LVT than with RT, and slightly lower for smaller immersion angles. In habitual loudness, transglottic pressure and frequency of oral pressure variation were lower for LVT phonation and amplitude of oral pressure variation was higher for LVT 2 cm in water. Some subjects preferred RT, whereas others preferred LVT or reported no differences between them.nConclusions. The tubes differed slightly in flow resistance. Higher oral pressure oscillation with LVT 2 cm in water may offer stronger massage effect on vocal folds.
Název v anglickém jazyce
Resonance Tube or Lax Vox?
Popis výsledku anglicky
Objective. This study compares the flow resistance of Resonance tube (RT) and Lax Vox tube (LVT) when submerged 2 cm and 10 cm in water, as well as phonation into the tubes in these conditions.nMethods. In the in vitro experiment, the air pressure for flow rates of 60-600 mL/s was measured at the tube inlet, when the outer end of the tube was submerged 2 cm and 10 cm below water surface in 30 degrees, 45 degrees, and 90 degrees angle. In the in vivo experiment, 14 subjects phonated in habitual loudness and loudly into both tubes, with the outer end 2 cm and 10 cm in water. RT was immersed in a 45 degrees angle and LVT in a 90 degrees angle in water. Oral pressure, contact quotient from electroglottographic signal, and sound pressure level were studied. Sensations during phonation were reported in an interview.nResults. Flow resistance was slightly lower with LVT than with RT, and slightly lower for smaller immersion angles. In habitual loudness, transglottic pressure and frequency of oral pressure variation were lower for LVT phonation and amplitude of oral pressure variation was higher for LVT 2 cm in water. Some subjects preferred RT, whereas others preferred LVT or reported no differences between them.nConclusions. The tubes differed slightly in flow resistance. Higher oral pressure oscillation with LVT 2 cm in water may offer stronger massage effect on vocal folds.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10307 - Acoustics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA16-01246S" target="_blank" >GA16-01246S: Počítačové a experimentální modelování samobuzených kmitů hlasivek a vliv jejich poškození na lidský hlas</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Voice
ISSN
0892-1997
e-ISSN
—
Svazek periodika
31
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
430-437
Kód UT WoS článku
000406147000006
EID výsledku v databázi Scopus
2-s2.0-85008430178