A frequency locked loop strategy for synchronization of inverters used in distributed energy sources
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388998%3A_____%2F19%3A00503249" target="_blank" >RIV/61388998:_____/19:00503249 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/19:00326835
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0142061518306586?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0142061518306586?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijepes.2018.11.004" target="_blank" >10.1016/j.ijepes.2018.11.004</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A frequency locked loop strategy for synchronization of inverters used in distributed energy sources
Popis výsledku v původním jazyce
A technique has been developed that incorporates the advantages of the cascaded delayed signal cancellation and dual second order generalized integrator schemes, the first one being used now as a pre-filter for the second element. A reconstructor block is applied as well to prevent unreal changes in the estimated frequency in case of phase angle jumps of the grid voltage. Experimental results are evaluated in terms of quality of the positive voltage sequence, frequency and phase angle identification for the grid voltage disturbed by harmonic and negative sequence components as well as for amplitude, frequency, and phase angle jumps in the voltage.
Název v anglickém jazyce
A frequency locked loop strategy for synchronization of inverters used in distributed energy sources
Popis výsledku anglicky
A technique has been developed that incorporates the advantages of the cascaded delayed signal cancellation and dual second order generalized integrator schemes, the first one being used now as a pre-filter for the second element. A reconstructor block is applied as well to prevent unreal changes in the estimated frequency in case of phase angle jumps of the grid voltage. Experimental results are evaluated in terms of quality of the positive voltage sequence, frequency and phase angle identification for the grid voltage disturbed by harmonic and negative sequence components as well as for amplitude, frequency, and phase angle jumps in the voltage.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrical Power & Energy Systems
ISSN
0142-0615
e-ISSN
—
Svazek periodika
107
Číslo periodika v rámci svazku
May
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
120-130
Kód UT WoS článku
000458221700012
EID výsledku v databázi Scopus
2-s2.0-85056998157