Precision half-life measurement of .sup.140 La with Ge-detector.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F02%3A49020023" target="_blank" >RIV/61389005:_____/02:49020023 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Precision half-life measurement of .sup.140 La with Ge-detector.
Popis výsledku v původním jazyce
Half-life is one of the fundamental properties od radioactive nuclei, and the presision required for its numerous applications in modern physics sometimes approaches the level of 10.sup.-4 -10.sup.-5. Most part of the T.sub.1/2 measurements performed upto now was made with proportional chambers, and the results were sometimes hardly reproducible within the error limits. Using Ge-detectors for that purpose brought some significant advantages but electronic unit related effects and spectra analysis procedures still remain the sources of the errors influencing the accuracy of the T.sub.1/2 attained. In this work, .sup.140 La sampleswere obtained in the .sup.139 La(n,.tau.).sup.140 La reastion,employing a microtron as a neutron source and the half-life measurements were performed with a HPGe-detector. Influencing factors such a photopeak and background shape, electronic circuitry dead time and deadtime variations during the measurements, as well as pulse pileup are studied altogether. Val
Název v anglickém jazyce
Precision half-life measurement of .sup.140 La with Ge-detector.
Popis výsledku anglicky
Half-life is one of the fundamental properties od radioactive nuclei, and the presision required for its numerous applications in modern physics sometimes approaches the level of 10.sup.-4 -10.sup.-5. Most part of the T.sub.1/2 measurements performed upto now was made with proportional chambers, and the results were sometimes hardly reproducible within the error limits. Using Ge-detectors for that purpose brought some significant advantages but electronic unit related effects and spectra analysis procedures still remain the sources of the errors influencing the accuracy of the T.sub.1/2 attained. In this work, .sup.140 La sampleswere obtained in the .sup.139 La(n,.tau.).sup.140 La reastion,employing a microtron as a neutron source and the half-life measurements were performed with a HPGe-detector. Influencing factors such a photopeak and background shape, electronic circuitry dead time and deadtime variations during the measurements, as well as pulse pileup are studied altogether. Val
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KSK1048102" target="_blank" >KSK1048102: Základní fyzikální zákony mikrosvěta a makrosvěta, chování hmoty a záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research. B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
187
Číslo periodika v rámci svazku
N/A
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
419-426
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—