Three types of detectors were used onboard the MIR station during the 28th base expeditions to characterise the radiation field: a linear energy transfer (LET)spectrometer was used to establish the LET spectrum between 7 and 700keV/mm corresponding mostly to secondary charged particles; a set of thermoluminescent detectors was used to characterise the low LET component of the onboard radiation field; and Si-diodes were installed to determine the contribution to the exposure due to fast neutrons. It wasfound out that the LET spectrum from secondary particles between 7 and 700 keV/mm does not depend on the external radiator: the average quality factors for the region mentioned are about 6.0 with ICRP 26 quality factors and about 6.8 with ICRP 60 qualityfactors. Both differential and integral LET spectra are presented for some typical cases, not only for particle number but also for the dose characteristics like dose and dose equivalent.
Název v anglickém jazyce
Dosimetry and Microdosimetry Characteristics Measured on Board the MIR Station during the 28th Basic Expedition.
Popis výsledku anglicky
Three types of detectors were used onboard the MIR station during the 28th base expeditions to characterise the radiation field: a linear energy transfer (LET)spectrometer was used to establish the LET spectrum between 7 and 700keV/mm corresponding mostly to secondary charged particles; a set of thermoluminescent detectors was used to characterise the low LET component of the onboard radiation field; and Si-diodes were installed to determine the contribution to the exposure due to fast neutrons. It wasfound out that the LET spectrum from secondary particles between 7 and 700 keV/mm does not depend on the external radiator: the average quality factors for the region mentioned are about 6.0 with ICRP 26 quality factors and about 6.8 with ICRP 60 qualityfactors. Both differential and integral LET spectra are presented for some typical cases, not only for particle number but also for the dose characteristics like dose and dose equivalent.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
539-543
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—