Biologicky vážená efektivní dávka v klinickém svazku protonů s energií 205 MeV
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F05%3A00000900" target="_blank" >RIV/61389005:_____/05:00000900 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biological weighted effective dose in 205 MeV clinical proton beam
Popis výsledku v původním jazyce
The contribution of high linear energy transfer (L) charged particles to dosimetric and microdosimetric characteristics in a clinical proton beam was experimentally studied using an ionization chamber and track etched detectors. The particles mentioned are produced by proton nuclear interactions; at the Bragg peak region slowed down protons also contribute in the L region above several keV ?m-1. Due to these particles the biological weighted effective dose (BWED) of the beam changes with depth. The spectra of particles with L above 7 keV ?m-1 were established by means of track etched detectors, which permitted us to determine their contribution to dosimetric and microdosimetric characteristics of clinical proton beams. The studies were realized in theclinical proton beam of the JINR Dubna Phasotron, with a primary energy of 205 MeV.
Název v anglickém jazyce
Biological weighted effective dose in 205 MeV clinical proton beam
Popis výsledku anglicky
The contribution of high linear energy transfer (L) charged particles to dosimetric and microdosimetric characteristics in a clinical proton beam was experimentally studied using an ionization chamber and track etched detectors. The particles mentioned are produced by proton nuclear interactions; at the Bragg peak region slowed down protons also contribute in the L region above several keV ?m-1. Due to these particles the biological weighted effective dose (BWED) of the beam changes with depth. The spectra of particles with L above 7 keV ?m-1 were established by means of track etched detectors, which permitted us to determine their contribution to dosimetric and microdosimetric characteristics of clinical proton beams. The studies were realized in theclinical proton beam of the JINR Dubna Phasotron, with a primary energy of 205 MeV.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physics in Medicine and Biology
ISSN
0031-9155
e-ISSN
—
Svazek periodika
50
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
281-287
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—