Odezva spektrometru LPE založeném na detektorech stop k protonům vysokých energií
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F05%3A00025766" target="_blank" >RIV/61389005:_____/05:00025766 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Response of a track-etch-based LET-spectrometer to high-energy protons
Popis výsledku v původním jazyce
Three PADC materials were used: 0.5 mm thick Page, 0.5 and 1 mm thick Tastrak; they were exposed to protons with energies up to 1000 MeV. Such energetic protons are generally not directly registrable in any of PADCs mentioned; the tracks observed correspond mostly to secondary particles created through nuclear interactions of primary protons. LET spectra permit to calculate the dose absorbed in the detector due to these secondary particles and to compare it with the ionization collision dose of primaryprotons. It is observed that the dose due to secondary particles represents a few percent of the ionization collision dose. Their ratio varies slightly with proton energy, and some differences between the three PADCs used were also observed. The importance of results obtained for on-board spacecraft dosimetry is analysed and discussed.
Název v anglickém jazyce
Response of a track-etch-based LET-spectrometer to high-energy protons
Popis výsledku anglicky
Three PADC materials were used: 0.5 mm thick Page, 0.5 and 1 mm thick Tastrak; they were exposed to protons with energies up to 1000 MeV. Such energetic protons are generally not directly registrable in any of PADCs mentioned; the tracks observed correspond mostly to secondary particles created through nuclear interactions of primary protons. LET spectra permit to calculate the dose absorbed in the detector due to these secondary particles and to compare it with the ionization collision dose of primaryprotons. It is observed that the dose due to secondary particles represents a few percent of the ionization collision dose. Their ratio varies slightly with proton energy, and some differences between the three PADCs used were also observed. The importance of results obtained for on-board spacecraft dosimetry is analysed and discussed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F04%2F0795" target="_blank" >GA202/04/0795: Charakteristiky přenosu energie nabitých částic s vysokým LPE na mikro- a makroskopické úrovni pro radioterapii, radiobiologii a radiační ochranu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
40
Číslo periodika v rámci svazku
2-6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
5
Strana od-do
575-579
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—