Měření difrakce neutronů a paprsků X na precipitátech mikro- a nanorozměrů v niklové superslitině a po jejich extrakci ze slitiny
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F06%3A00078915" target="_blank" >RIV/61389005:_____/06:00078915 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron and X-ray diffraction measurements on micro- and nano-sized precipitates embedded in a Ni-based superalloy and after their extraction from the alloy
Popis výsledku v původním jazyce
Neutron and X-ray diffraction are eminently suitable techniques to determine lattice misfit in nickel-based superalloys. Due to the different measuring techniques and sensitivities of the probes, sometimes one method is preferable to the other. This paper demonstrates how the use of neutrons allows a better determination of the misfit value in a bulk single-crystal tungsten-rich nickel superalloy with oriented precipitates than the use of X-rays, although the resolution in neutron diffraction is generally inferior to that in X-ray diffraction. It also yields more accurate results when the precipitates are at the nanoscale. The neutron measurements were carried out using a special technique to detect a larger number of reflections in single-crystal samples than observed in standard diffraction geometry. A comparison of the measurements by neutron and X-ray diffraction of precipitates separated from the bulk is also included in the investigation.
Název v anglickém jazyce
Neutron and X-ray diffraction measurements on micro- and nano-sized precipitates embedded in a Ni-based superalloy and after their extraction from the alloy
Popis výsledku anglicky
Neutron and X-ray diffraction are eminently suitable techniques to determine lattice misfit in nickel-based superalloys. Due to the different measuring techniques and sensitivities of the probes, sometimes one method is preferable to the other. This paper demonstrates how the use of neutrons allows a better determination of the misfit value in a bulk single-crystal tungsten-rich nickel superalloy with oriented precipitates than the use of X-rays, although the resolution in neutron diffraction is generally inferior to that in X-ray diffraction. It also yields more accurate results when the precipitates are at the nanoscale. The neutron measurements were carried out using a special technique to detect a larger number of reflections in single-crystal samples than observed in standard diffraction geometry. A comparison of the measurements by neutron and X-ray diffraction of precipitates separated from the bulk is also included in the investigation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F06%2F0601" target="_blank" >GA202/06/0601: Fokusující monochromátory a analyzátory pro difraktometrii a spektrometrii termálních neutronů</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Materialia
ISSN
1359-6454
e-ISSN
—
Svazek periodika
54
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
1307-1316