Stanovení jódu v potravinách konzumovaných v Libyi s použitím instrumentální a radiochemické neutronové aktavační analýzy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F06%3A00078918" target="_blank" >RIV/61389005:_____/06:00078918 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of iodine in foodstuffs consumed in Libya using instrumental and radiochemical neutro activation analysis
Popis výsledku v původním jazyce
Iodine was determined in foodstuffs consumed in Libya employing two modes of NAA.The first mode was instrumental using short-time irradiation with epithermal neutrons behind a Cd shield(EINAA). The other mode utilized shor-time irradiation with the reactor-pile neutrons followed by radiochemical separation (RNAA). The radiochemical separation procedure was based on the alkaline-oxidative fusion of samples and extraction of elemental iodine into chloroform. Separation yield determined using the radiotracer131 I was within the range of 90 to 95%. For guality control purposes,standard reference materials were analyzed in both modes employed.Using RNAA, a decection limit of ~1 ng g -1 could be obtained indicating superiority of the method in measuring ultra-trace levels of iodine. On the other hand, more than one order of magnitude higher detection limit did not allow sufficiently accurate determination of iodine in Libyan foodstuffs using EINAA.
Název v anglickém jazyce
Determination of iodine in foodstuffs consumed in Libya using instrumental and radiochemical neutro activation analysis
Popis výsledku anglicky
Iodine was determined in foodstuffs consumed in Libya employing two modes of NAA.The first mode was instrumental using short-time irradiation with epithermal neutrons behind a Cd shield(EINAA). The other mode utilized shor-time irradiation with the reactor-pile neutrons followed by radiochemical separation (RNAA). The radiochemical separation procedure was based on the alkaline-oxidative fusion of samples and extraction of elemental iodine into chloroform. Separation yield determined using the radiotracer131 I was within the range of 90 to 95%. For guality control purposes,standard reference materials were analyzed in both modes employed.Using RNAA, a decection limit of ~1 ng g -1 could be obtained indicating superiority of the method in measuring ultra-trace levels of iodine. On the other hand, more than one order of magnitude higher detection limit did not allow sufficiently accurate determination of iodine in Libyan foodstuffs using EINAA.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Czechoslovak Journal of Physics
ISSN
0011-4626
e-ISSN
—
Svazek periodika
-
Číslo periodika v rámci svazku
56
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
159-163
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—