In-beam measurements of the HADES-TOF RPC wall
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F09%3A00337837" target="_blank" >RIV/61389005:_____/09:00337837 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In-beam measurements of the HADES-TOF RPC wall
Popis výsledku v původním jazyce
A full size prototype of the new inner High-Acceptance DiElectron Spectrometer (HADES)-TOF wall based on Resistive Plate Chambers (RPCs) was mounted and exposed to secondaries from C reactions on Be and Nb targets at 2AGeV kinetic energy and typical HADES particle fluxes. The tested sextant is constituted by 187 individual 4-gap glass-aluminium shielded RPC cells distributed in three columns and two layers, covering an area of 1.26 m(2). An average timing resolution of 73 ps sigma was measured with 99%intrinsic efficiency, on a random location, and moderate timing tails, along with an average longitudinal position resolution of 7.7 mm sigma, in the range from a few Hz/cm(2) up to 80Hz/cm(2) without noticeable degradation of performance. Additionally,the matching efficiency was estimated using the tracking system of HADES, yielding an average value of 97.5%.
Název v anglickém jazyce
In-beam measurements of the HADES-TOF RPC wall
Popis výsledku anglicky
A full size prototype of the new inner High-Acceptance DiElectron Spectrometer (HADES)-TOF wall based on Resistive Plate Chambers (RPCs) was mounted and exposed to secondaries from C reactions on Be and Nb targets at 2AGeV kinetic energy and typical HADES particle fluxes. The tested sextant is constituted by 187 individual 4-gap glass-aluminium shielded RPC cells distributed in three columns and two layers, covering an area of 1.26 m(2). An average timing resolution of 73 ps sigma was measured with 99%intrinsic efficiency, on a random location, and moderate timing tails, along with an average longitudinal position resolution of 7.7 mm sigma, in the range from a few Hz/cm(2) up to 80Hz/cm(2) without noticeable degradation of performance. Additionally,the matching efficiency was estimated using the tracking system of HADES, yielding an average value of 97.5%.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
602
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000266226400016
EID výsledku v databázi Scopus
—