Spectra of linear energy transfer and other dosimetry characteristics as measured in C290 mev/n MONO and SOBP ion beams at HIMAC-bio (NIRS, Japan) with different detectors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F11%3A00360523" target="_blank" >RIV/61389005:_____/11:00360523 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1093/rpd/ncq532" target="_blank" >http://dx.doi.org/10.1093/rpd/ncq532</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncq532" target="_blank" >10.1093/rpd/ncq532</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spectra of linear energy transfer and other dosimetry characteristics as measured in C290 mev/n MONO and SOBP ion beams at HIMAC-bio (NIRS, Japan) with different detectors
Popis výsledku v původním jazyce
Active mobile dosimetry unit (Liulin), passive plastic nuclear track detectors (PNTD) and thermoluminescent detectors (TLD) were exposed in a C290 MeV/n beam at HIMAC?BIO (NIRS, Japan). Two different types of beam configuration were use: monoenergetic (MONO) and spread-out Bragg peak (SOBP). Relative response of TLDs in was re-proved to be dependent on the linear energy transfer (LET). Liulin is able to measure perpendicularly incident charged particles up to similar to 7 to 35 keV/mm (in water), PNTD can measure from similar to 7 to 400 keV/um, independently of the registration angle. The results from both methods are compared and combined for both beams? configuration, and a good agreement is observed.
Název v anglickém jazyce
Spectra of linear energy transfer and other dosimetry characteristics as measured in C290 mev/n MONO and SOBP ion beams at HIMAC-bio (NIRS, Japan) with different detectors
Popis výsledku anglicky
Active mobile dosimetry unit (Liulin), passive plastic nuclear track detectors (PNTD) and thermoluminescent detectors (TLD) were exposed in a C290 MeV/n beam at HIMAC?BIO (NIRS, Japan). Two different types of beam configuration were use: monoenergetic (MONO) and spread-out Bragg peak (SOBP). Relative response of TLDs in was re-proved to be dependent on the linear energy transfer (LET). Liulin is able to measure perpendicularly incident charged particles up to similar to 7 to 35 keV/mm (in water), PNTD can measure from similar to 7 to 400 keV/um, independently of the registration angle. The results from both methods are compared and combined for both beams? configuration, and a good agreement is observed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
143
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
519-522
Kód UT WoS článku
000288022300076