PHITS simulations of the Protective curtain experiment onboard the Service module of ISS: Comparison with absorbed doses measured with TLDs
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F13%3A00424382" target="_blank" >RIV/61389005:_____/13:00424382 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.asr.2013.08.025" target="_blank" >http://dx.doi.org/10.1016/j.asr.2013.08.025</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.asr.2013.08.025" target="_blank" >10.1016/j.asr.2013.08.025</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PHITS simulations of the Protective curtain experiment onboard the Service module of ISS: Comparison with absorbed doses measured with TLDs
Popis výsledku v původním jazyce
The reducing effect of the Protective curtain was studied by comparing the calculated absorbed doses in shielded and unshielded detectors separately for the TPs and GCRs. In case of TPs, the reducing effect was larger than 60% and 40% for pairs of detectors located at aluminum wall and at crew cabin window, respectively. In case of GCRs, small shielding effect was observed for detectors located behind the window but for those located behind the aluminum wall, the effect was even opposite: the absorbed doses in the unshielded detectors were about 10% lower than in the shielded ones. This result was confirmed by the depth-dose analysis using rectangular source emitting broad parallel incident particles impinging on the simple geometry composed of aluminum/glass box and water box of variable thickness simulating the spacecraft wall/window and Protective curtain, respectively. The additional dose in the shielded detectors is related to the secondary fragments known as the "wall effect". Ho
Název v anglickém jazyce
PHITS simulations of the Protective curtain experiment onboard the Service module of ISS: Comparison with absorbed doses measured with TLDs
Popis výsledku anglicky
The reducing effect of the Protective curtain was studied by comparing the calculated absorbed doses in shielded and unshielded detectors separately for the TPs and GCRs. In case of TPs, the reducing effect was larger than 60% and 40% for pairs of detectors located at aluminum wall and at crew cabin window, respectively. In case of GCRs, small shielding effect was observed for detectors located behind the window but for those located behind the aluminum wall, the effect was even opposite: the absorbed doses in the unshielded detectors were about 10% lower than in the shielded ones. This result was confirmed by the depth-dose analysis using rectangular source emitting broad parallel incident particles impinging on the simple geometry composed of aluminum/glass box and water box of variable thickness simulating the spacecraft wall/window and Protective curtain, respectively. The additional dose in the shielded detectors is related to the secondary fragments known as the "wall effect". Ho
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advances in Space Research
ISSN
0273-1177
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1911-1918
Kód UT WoS článku
000328521500006
EID výsledku v databázi Scopus
—