Simulating radial dose of ion tracks in liquid water simulated with Geant4-DNA: A comparative study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F14%3A00432978" target="_blank" >RIV/61389005:_____/14:00432978 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nimb.2014.04.025" target="_blank" >http://dx.doi.org/10.1016/j.nimb.2014.04.025</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nimb.2014.04.025" target="_blank" >10.1016/j.nimb.2014.04.025</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simulating radial dose of ion tracks in liquid water simulated with Geant4-DNA: A comparative study
Popis výsledku v původním jazyce
An accurate modeling of radial energy deposition around ion tracks is a key requirement of radiation transport software used for simulations in radiobiology at the sub-cellular scale. The work presented in this paper is part of the on-going benchmarkingof the "Geant4-DNA" physics processes and models, which are available in the Geant4 Monte Carlo simulation toolkit for the low energy transport of particles in liquid water. We present for the first time radial dose distributions of incident ion tracks simulated with "Geant4-DNA". Simulation results are compared to other results available in the literature, obtained from analytical calculations, step-by-step Monte Carlo simulations and measurements. They show a reasonable agreement with reference data.
Název v anglickém jazyce
Simulating radial dose of ion tracks in liquid water simulated with Geant4-DNA: A comparative study
Popis výsledku anglicky
An accurate modeling of radial energy deposition around ion tracks is a key requirement of radiation transport software used for simulations in radiobiology at the sub-cellular scale. The work presented in this paper is part of the on-going benchmarkingof the "Geant4-DNA" physics processes and models, which are available in the Geant4 Monte Carlo simulation toolkit for the low energy transport of particles in liquid water. We present for the first time radial dose distributions of incident ion tracks simulated with "Geant4-DNA". Simulation results are compared to other results available in the literature, obtained from analytical calculations, step-by-step Monte Carlo simulations and measurements. They show a reasonable agreement with reference data.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
333
Číslo periodika v rámci svazku
AUG
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
92-98
Kód UT WoS článku
000339137600013
EID výsledku v databázi Scopus
—