Nondestructive assay of fluorine in geological and other materials by instrumental photon activation analysis with a microtron
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00442891" target="_blank" >RIV/61389005:_____/15:00442891 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985891:_____/15:00444039
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nimb.2014.09.023" target="_blank" >http://dx.doi.org/10.1016/j.nimb.2014.09.023</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nimb.2014.09.023" target="_blank" >10.1016/j.nimb.2014.09.023</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Nondestructive assay of fluorine in geological and other materials by instrumental photon activation analysis with a microtron
Popis výsledku v původním jazyce
The present paper examines possibilities of non-destructive determination of fluorine, mainly in minerals, rocks and coal, by instrumental photon activation analysis (IPAA) using the MT-25 microtron. The fluorine assay consists of counting the positron-electron annihilation line of F-18 at 511 key, which is a product of the photonuclear reaction F-19(gamma,n)F-18 and a pure positron emitter. The assay is complicated by the simultaneous formation of other positron emitters. The main contributors to interference in geological samples are from Ti-48 and Cl-34m, whereas those from Sc-44 and Zr-89 are minor. Optimizing beam energy and irradiation-decay-counting times, together with using interfering element calibration standards, allowed reliable IPAA determination of fluorine in selected USGS and CRPG geochemical reference materials, NIST coal reference materials, and NIST RM 8414 Bovine Muscle. In agreement with the published data obtained by PIGE, the results of the F assay by IPAA have
Název v anglickém jazyce
Nondestructive assay of fluorine in geological and other materials by instrumental photon activation analysis with a microtron
Popis výsledku anglicky
The present paper examines possibilities of non-destructive determination of fluorine, mainly in minerals, rocks and coal, by instrumental photon activation analysis (IPAA) using the MT-25 microtron. The fluorine assay consists of counting the positron-electron annihilation line of F-18 at 511 key, which is a product of the photonuclear reaction F-19(gamma,n)F-18 and a pure positron emitter. The assay is complicated by the simultaneous formation of other positron emitters. The main contributors to interference in geological samples are from Ti-48 and Cl-34m, whereas those from Sc-44 and Zr-89 are minor. Optimizing beam energy and irradiation-decay-counting times, together with using interfering element calibration standards, allowed reliable IPAA determination of fluorine in selected USGS and CRPG geochemical reference materials, NIST coal reference materials, and NIST RM 8414 Bovine Muscle. In agreement with the published data obtained by PIGE, the results of the F assay by IPAA have
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
342
Číslo periodika v rámci svazku
JAN
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
82-86
Kód UT WoS článku
000347770500012