Innovations at the MT 25 microtron aimed at applications in photon activation analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00443437" target="_blank" >RIV/61389005:_____/15:00443437 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10967-014-3578-z" target="_blank" >http://dx.doi.org/10.1007/s10967-014-3578-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10967-014-3578-z" target="_blank" >10.1007/s10967-014-3578-z</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Innovations at the MT 25 microtron aimed at applications in photon activation analysis
Popis výsledku v původním jazyce
Microtron MT 25 is an effective source of high energy photon radiation in photon activation analysis (PAA). Recent modernization of MT 25 was aimed at upgrading its parameters such as the mean accelerated electron current, quality of the beam and irradiation fields, and long-run operation stability and reliability. A fuzzy system for automated control of the current and energy of the accelerated electrons has been designed. Installation of an automated pneumatic tube delivery system for rapid sample transport between the beam position and detector will provide extension of the analytical range of PAA in the short time irradiation mode.
Název v anglickém jazyce
Innovations at the MT 25 microtron aimed at applications in photon activation analysis
Popis výsledku anglicky
Microtron MT 25 is an effective source of high energy photon radiation in photon activation analysis (PAA). Recent modernization of MT 25 was aimed at upgrading its parameters such as the mean accelerated electron current, quality of the beam and irradiation fields, and long-run operation stability and reliability. A fuzzy system for automated control of the current and energy of the accelerated electrons has been designed. Installation of an automated pneumatic tube delivery system for rapid sample transport between the beam position and detector will provide extension of the analytical range of PAA in the short time irradiation mode.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
—
Svazek periodika
304
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
183-188
Kód UT WoS článku
000351755200029