Determination of Trace Concentration in TMD Detectors using PGAA
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00447611" target="_blank" >RIV/61389005:_____/15:00447611 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/26722445:_____/15:#0001075
Výsledek na webu
<a href="http://dx.doi.org/10.1051/epjconf/20159308003" target="_blank" >http://dx.doi.org/10.1051/epjconf/20159308003</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20159308003" target="_blank" >10.1051/epjconf/20159308003</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of Trace Concentration in TMD Detectors using PGAA
Popis výsledku v původním jazyce
Transmutation detectors could be alternative to the traditional activation detector method for neutron fluence dosimetry at power nuclear reactors. This new method require an isotopically highly-sensitive, non-destructive in sense of compactness as wellas isotopic content, precise and standardly used analytical method for trace concentration determination. The capability of Prompt Gamma-ray Activation Analysis (PGAA) for determination of trace concentrations of transmuted stable nuclides in the metallic foils of Ni, Au, Cu and Nb, which were irradiated for 21 days in the reactor core at the LVR-15 research reactor in Rez, is reported. The PGAA measurements of these activation foils were performed at the PGAA facility at Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRMII) in Garching.
Název v anglickém jazyce
Determination of Trace Concentration in TMD Detectors using PGAA
Popis výsledku anglicky
Transmutation detectors could be alternative to the traditional activation detector method for neutron fluence dosimetry at power nuclear reactors. This new method require an isotopically highly-sensitive, non-destructive in sense of compactness as wellas isotopic content, precise and standardly used analytical method for trace concentration determination. The capability of Prompt Gamma-ray Activation Analysis (PGAA) for determination of trace concentrations of transmuted stable nuclides in the metallic foils of Ni, Au, Cu and Nb, which were irradiated for 21 days in the reactor core at the LVR-15 research reactor in Rez, is reported. The PGAA measurements of these activation foils were performed at the PGAA facility at Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRMII) in Garching.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
978-2-7598-1794-8
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
E D P Sciences
Místo vydání
Cedex
Místo konání akce
Dresden
Datum konání akce
25. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000358307500114