Development and testing of a new system for irradiation and subsequent processing of Lu-176 target. Material and Methods: A new type of an irradiation vessel consisting of external aluminum alloy cover and inner quartz tube for sample placement was designed and tested. The system is water-proof. The ampoule was designed as disposable and has been tested for He leak - achieved leakage level was in order of 2E-09 mbar.l/s and in a real irradiation conditions.Results: Experiments performed under the highest available neutron flux density have shown reproducible behaviour of the systems regarding leakage, target processing and activity recovery.Conclusion: The designed system demonstrated suitability for high-level activities production of reactor medicalradionuclides, in particular of Lu-177.
Název v anglickém jazyce
New system for production of reactor medical radionuclides tested with Lu-176
Popis výsledku anglicky
Development and testing of a new system for irradiation and subsequent processing of Lu-176 target. Material and Methods: A new type of an irradiation vessel consisting of external aluminum alloy cover and inner quartz tube for sample placement was designed and tested. The system is water-proof. The ampoule was designed as disposable and has been tested for He leak - achieved leakage level was in order of 2E-09 mbar.l/s and in a real irradiation conditions.Results: Experiments performed under the highest available neutron flux density have shown reproducible behaviour of the systems regarding leakage, target processing and activity recovery.Conclusion: The designed system demonstrated suitability for high-level activities production of reactor medicalradionuclides, in particular of Lu-177.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2011019" target="_blank" >LM2011019: CANAM ? příspěvek k provozu a k reinvesticím Centra urychlovačů a jaderných analytických metod</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů