Radiolabeling of antibody for epitope of human carbonic anhydrase IX (IgG M75) by 61Cu and 64Cu and its biological testing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00450524" target="_blank" >RIV/61389005:_____/15:00450524 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68378050:_____/15:00450524
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Radiolabeling of antibody for epitope of human carbonic anhydrase IX (IgG M75) by 61Cu and 64Cu and its biological testing
Popis výsledku v původním jazyce
Human carbonic anhydrase IX is a membrane enzyme that is significantly expressed in some types of cancer cells. The antibody IgG M75 was successfully conjugated with a new, copper-specific chelator ?phosphinate, the conjugation method was optimized and is well-reproducible. The conjugate was then labelled with two positron emitting copper radioisotopes, Cu-61 (3.333 h) and Cu-64 (12.701 h). Labelled conjugates were tested in vivo in mice with colorectal cancer xenografts. Copper radioisotopes were produced via Ni-nat(d,x) and Ni-64(p,n) reactions (Ni, 99.999 %, Goodfellow; Ni-64, 99.09 %, Isoflex). Specific activity of Cu-61 was 1 GBq/mg Cu and more, which was satisfactory for the labelling purposes. All reagents were analytical grade and were purifiedprior labelling with chelex-100 in sodium form, 100-200 mesh from metals surplus. Chelator ?phospinate was synthesized and characterized in our laboratories. Antibody IgG M75 was prepared by genetic engineering methods. Immunoconjugates
Název v anglickém jazyce
Radiolabeling of antibody for epitope of human carbonic anhydrase IX (IgG M75) by 61Cu and 64Cu and its biological testing
Popis výsledku anglicky
Human carbonic anhydrase IX is a membrane enzyme that is significantly expressed in some types of cancer cells. The antibody IgG M75 was successfully conjugated with a new, copper-specific chelator ?phosphinate, the conjugation method was optimized and is well-reproducible. The conjugate was then labelled with two positron emitting copper radioisotopes, Cu-61 (3.333 h) and Cu-64 (12.701 h). Labelled conjugates were tested in vivo in mice with colorectal cancer xenografts. Copper radioisotopes were produced via Ni-nat(d,x) and Ni-64(p,n) reactions (Ni, 99.999 %, Goodfellow; Ni-64, 99.09 %, Isoflex). Specific activity of Cu-61 was 1 GBq/mg Cu and more, which was satisfactory for the labelling purposes. All reagents were analytical grade and were purifiedprior labelling with chelex-100 in sodium form, 100-200 mesh from metals surplus. Chelator ?phospinate was synthesized and characterized in our laboratories. Antibody IgG M75 was prepared by genetic engineering methods. Immunoconjugates
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů