Edge Refraction Contrast Imaging on a Coventional Neutron Diffractometer Employing Dispersive Double-Crystal Monochromator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00451712" target="_blank" >RIV/61389005:_____/15:00451712 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.phpro.2015.07.045" target="_blank" >http://dx.doi.org/10.1016/j.phpro.2015.07.045</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.phpro.2015.07.045" target="_blank" >10.1016/j.phpro.2015.07.045</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Edge Refraction Contrast Imaging on a Coventional Neutron Diffractometer Employing Dispersive Double-Crystal Monochromator
Popis výsledku v původním jazyce
Slits and macroscopic objects such as edges give rise to interference effects when a coherent neutron (or X-ray) beam propagates through an investigated sample. These phenomena are effectively used in the so called phase-contrast imaging. In addition tothe absorption contrast in the conventional radiography it exploits also these contributions from the induced phase shifts. However, the used radiation has to possess a sufficiently high spatial coherence. In this contribution we present a special neutron diffractometer performance (in two alternatives A and B) based on two bent perfect Si crystals which provides a high spatial coherence beam of sufficient intensity which could be potentially used in some phase contrast radiography experiments.
Název v anglickém jazyce
Edge Refraction Contrast Imaging on a Coventional Neutron Diffractometer Employing Dispersive Double-Crystal Monochromator
Popis výsledku anglicky
Slits and macroscopic objects such as edges give rise to interference effects when a coherent neutron (or X-ray) beam propagates through an investigated sample. These phenomena are effectively used in the so called phase-contrast imaging. In addition tothe absorption contrast in the conventional radiography it exploits also these contributions from the induced phase shifts. However, the used radiation has to possess a sufficiently high spatial coherence. In this contribution we present a special neutron diffractometer performance (in two alternatives A and B) based on two bent perfect Si crystals which provides a high spatial coherence beam of sufficient intensity which could be potentially used in some phase contrast radiography experiments.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Physics Procedia
ISBN
—
ISSN
1875-3892
e-ISSN
—
Počet stran výsledku
7
Strana od-do
320-326
Název nakladatele
Elsevier
Místo vydání
Nizozemí
Místo konání akce
Grindelwald
Datum konání akce
5. 10. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—