New type of versatile neutron diffractometer with a double-crystal monochromator system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00451717" target="_blank" >RIV/61389005:_____/15:00451717 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1017/S0885715614001201" target="_blank" >http://dx.doi.org/10.1017/S0885715614001201</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1017/S0885715614001201" target="_blank" >10.1017/S0885715614001201</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New type of versatile neutron diffractometer with a double-crystal monochromator system
Popis výsledku v původním jazyce
Properties of a special double-crystal (DC) monochromator employing bent-perfect crystals of Si in (1, 1) and (n, m) settings are presented. The first monochromator was the bent Si(111) crystal (4 mm thickness) and the second one was in the form of a sandwich consisting of two bent Si (111) and Si(220) slabs (2 and 1.3 mm thickness, respectively). It has been found that by a simple exchange of diffraction conditions on the second monochromator one can use either Si(111) + Si (111) bent crystals in (1, 1) setting providing good luminosity and worse diffractometer resolution or Si(111) + Si(220) bent crystals in quasi-dispersive (n, m) setting providing very good diffractometer resolution and correspondingly weaker luminosity. It has been found that besides an excellent focusing and reflectivity properties of the dispersive double-bent-crystal setting the obtained monochromatic neutron current is sufficiently high for diffraction experiments even at the mediumpower research reactor.
Název v anglickém jazyce
New type of versatile neutron diffractometer with a double-crystal monochromator system
Popis výsledku anglicky
Properties of a special double-crystal (DC) monochromator employing bent-perfect crystals of Si in (1, 1) and (n, m) settings are presented. The first monochromator was the bent Si(111) crystal (4 mm thickness) and the second one was in the form of a sandwich consisting of two bent Si (111) and Si(220) slabs (2 and 1.3 mm thickness, respectively). It has been found that by a simple exchange of diffraction conditions on the second monochromator one can use either Si(111) + Si (111) bent crystals in (1, 1) setting providing good luminosity and worse diffractometer resolution or Si(111) + Si(220) bent crystals in quasi-dispersive (n, m) setting providing very good diffractometer resolution and correspondingly weaker luminosity. It has been found that besides an excellent focusing and reflectivity properties of the dispersive double-bent-crystal setting the obtained monochromatic neutron current is sufficiently high for diffraction experiments even at the mediumpower research reactor.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BM - Fyzika pevných látek a magnetismus
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Powder Diffraction
ISSN
0885-7156
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
CA - Kanada
Počet stran výsledku
6
Strana od-do
41-46
Kód UT WoS článku
000370164300008
EID výsledku v databázi Scopus
2-s2.0-84929843609