Determination of the separation efficiencies of a single-stage cryogenic distillation setup to remove krypton out of xenon by using a Kr-83m tracer method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F15%3A00454095" target="_blank" >RIV/61389005:_____/15:00454095 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4934978" target="_blank" >http://dx.doi.org/10.1063/1.4934978</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4934978" target="_blank" >10.1063/1.4934978</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of the separation efficiencies of a single-stage cryogenic distillation setup to remove krypton out of xenon by using a Kr-83m tracer method
Popis výsledku v původním jazyce
The separation of krypton and xenon is of particular importance for the field of direct dark matter search with liquid xenon detectors. The intrinsic contamination of the xenon with radioactive Kr-85 makes a significant background for these kinds of lowcount-rate experiments and has to be removed beforehand. This can be achieved by cryogenic distillation, a technique widely used in industry, using the different vapor pressures of krypton and xenon. In this paper, we present an investigation on the separation performance of a single stage distillation system using a radioactive Kr-83m-tracer method. The separation characteristics under different operation conditions are determined for very low concentrations of krypton in xenon at the level of Kr-83m/Xe = 1.9 . 10(-15), demonstrating, that cryogenic distillation in this regime is working. The observed separation is in agreement with the expectation from the different volatilities of krypton and xenon. This cryogenic distillation statio
Název v anglickém jazyce
Determination of the separation efficiencies of a single-stage cryogenic distillation setup to remove krypton out of xenon by using a Kr-83m tracer method
Popis výsledku anglicky
The separation of krypton and xenon is of particular importance for the field of direct dark matter search with liquid xenon detectors. The intrinsic contamination of the xenon with radioactive Kr-85 makes a significant background for these kinds of lowcount-rate experiments and has to be removed beforehand. This can be achieved by cryogenic distillation, a technique widely used in industry, using the different vapor pressures of krypton and xenon. In this paper, we present an investigation on the separation performance of a single stage distillation system using a radioactive Kr-83m-tracer method. The separation characteristics under different operation conditions are determined for very low concentrations of krypton in xenon at the level of Kr-83m/Xe = 1.9 . 10(-15), demonstrating, that cryogenic distillation in this regime is working. The observed separation is in agreement with the expectation from the different volatilities of krypton and xenon. This cryogenic distillation statio
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
86
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
—
Kód UT WoS článku
000366054300055
EID výsledku v databázi Scopus
2-s2.0-84946763831