DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F16%3A00506282" target="_blank" >RIV/61389005:_____/16:00506282 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/16:00309332
Výsledek na webu
<a href="https://doi.org/10.1088/1748-0221/11/11/P11011" target="_blank" >https://doi.org/10.1088/1748-0221/11/11/P11011</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/11/11/P11011" target="_blank" >10.1088/1748-0221/11/11/P11011</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
Popis výsledku v původním jazyce
The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1m(3). High segmentation of the plastic scintillator will allow to suppress a background down to a similar to 1% level. Numerous tests performed with a simplified pilot prototype DANSSino under a 3GW(th) reactor of the Kalinin NPP have demonstrated operability of the chosen design. nnThe DANSS detector surrounded with a composite shield is movable by means of a special lifting gear, varying the distance to the reactor core in a range from 10m to 12 m. Due to this feature, it could be used not only for the reactor monitoring, but also for fundamental research including short-range neutrino oscillations to the sterile state. Supposing one-year measurement, the sensitivity to the oscillation parameters is expected to reach a level of sin(2)( 2 theta (new)) similar to 5 x 10(-3) with Delta m(2) subset of (0 : 02-5 : 0) eV(2).
Název v anglickém jazyce
DANSS: Detector of the reactor AntiNeutrino based on Solid Scintillator
Popis výsledku anglicky
The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1m(3). High segmentation of the plastic scintillator will allow to suppress a background down to a similar to 1% level. Numerous tests performed with a simplified pilot prototype DANSSino under a 3GW(th) reactor of the Kalinin NPP have demonstrated operability of the chosen design. nnThe DANSS detector surrounded with a composite shield is movable by means of a special lifting gear, varying the distance to the reactor core in a range from 10m to 12 m. Due to this feature, it could be used not only for the reactor monitoring, but also for fundamental research including short-range neutrino oscillations to the sterile state. Supposing one-year measurement, the sensitivity to the oscillation parameters is expected to reach a level of sin(2)( 2 theta (new)) similar to 5 x 10(-3) with Delta m(2) subset of (0 : 02-5 : 0) eV(2).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LG14004" target="_blank" >LG14004: Spolupráce ČR s SÚJV Dubna v teoretické a jaderné fyzice a při využití jaderných metod v dalších oborech</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
29
Strana od-do
P11011
Kód UT WoS článku
000395673100011
EID výsledku v databázi Scopus
2-s2.0-84999863236