Dose distribution of secondary radiation in a water phantom for a proton pencil beam-EURADOS WG9 intercomparison exercise
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F18%3A00489292" target="_blank" >RIV/61389005:_____/18:00489292 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1361-6560/aab469" target="_blank" >http://dx.doi.org/10.1088/1361-6560/aab469</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1361-6560/aab469" target="_blank" >10.1088/1361-6560/aab469</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dose distribution of secondary radiation in a water phantom for a proton pencil beam-EURADOS WG9 intercomparison exercise
Popis výsledku v původním jazyce
Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 x 300 x 600 mm(3) water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 ((LiF)-Li-7:Mg, Ti), MTS-6 ((LiF)-Li-6:Mg, Ti), MTS-N ((LiF)-Li-nat:Mg, Ti) and TLD-700 ((LiF)-Li-7: Mg, Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 x 100 x 100 mm(3) (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy(-1) at a distance of 100 mm and 0.02 mGy Gy(-1) at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be similar to 0.7 and similar to 0.06 mSv Gy(-1), respectively. The measured neutron doses were comparable with the out-offield neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.
Název v anglickém jazyce
Dose distribution of secondary radiation in a water phantom for a proton pencil beam-EURADOS WG9 intercomparison exercise
Popis výsledku anglicky
Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300 x 300 x 600 mm(3) water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 ((LiF)-Li-7:Mg, Ti), MTS-6 ((LiF)-Li-6:Mg, Ti), MTS-N ((LiF)-Li-nat:Mg, Ti) and TLD-700 ((LiF)-Li-7: Mg, Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100 x 100 x 100 mm(3) (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy(-1) at a distance of 100 mm and 0.02 mGy Gy(-1) at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be similar to 0.7 and similar to 0.06 mSv Gy(-1), respectively. The measured neutron doses were comparable with the out-offield neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physics in Medicine and Biology
ISSN
0031-9155
e-ISSN
—
Svazek periodika
63
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
—
Kód UT WoS článku
000430476400007
EID výsledku v databázi Scopus
2-s2.0-85046457369