Intercomparison of LET spectra measured with Timepix and TEPC in reference radiation field CERF
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F18%3A00495581" target="_blank" >RIV/61389005:_____/18:00495581 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/AERO.2018.8396749" target="_blank" >http://dx.doi.org/10.1109/AERO.2018.8396749</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/AERO.2018.8396749" target="_blank" >10.1109/AERO.2018.8396749</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intercomparison of LET spectra measured with Timepix and TEPC in reference radiation field CERF
Popis výsledku v původním jazyce
Radiation field onboard aircraft is composed of many particles (neutrons, protons, alphas, muons, electrons, positrons, and gamma) with large scale of energies. Proper experimental evaluation of the radiation risk is therefore a difficult task requiring a set of dosimeters. For measurement with a single radaition detector, the tissue equivalent proportional counter (TEPC) is usualy used as a reference dosimeter. However, the TEPC device is still big and heavy for routine measurements. We therefore study new methods based on a single silicon chip. From them, Timepix is a very interesting option taking advantage of its ability to record tracks of radiation in the silicon chip in real time. We developed a new method for evaluation of LET in water using Timepix with the single silicon chip. CERF (The CERN's EU Reference Field Facility) is the reference field facility built for calibration of dosimeters used onboard aircraft. We exposed both detectors (TEPC Hawk and Timepix) to the radiation in the same reference positions and compared the results. Good agreement was observed.
Název v anglickém jazyce
Intercomparison of LET spectra measured with Timepix and TEPC in reference radiation field CERF
Popis výsledku anglicky
Radiation field onboard aircraft is composed of many particles (neutrons, protons, alphas, muons, electrons, positrons, and gamma) with large scale of energies. Proper experimental evaluation of the radiation risk is therefore a difficult task requiring a set of dosimeters. For measurement with a single radaition detector, the tissue equivalent proportional counter (TEPC) is usualy used as a reference dosimeter. However, the TEPC device is still big and heavy for routine measurements. We therefore study new methods based on a single silicon chip. From them, Timepix is a very interesting option taking advantage of its ability to record tracks of radiation in the silicon chip in real time. We developed a new method for evaluation of LET in water using Timepix with the single silicon chip. CERF (The CERN's EU Reference Field Facility) is the reference field facility built for calibration of dosimeters used onboard aircraft. We exposed both detectors (TEPC Hawk and Timepix) to the radiation in the same reference positions and compared the results. Good agreement was observed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20304 - Aerospace engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IEEE Aerospace Conference proceedings
ISBN
9781538620144
ISSN
1095-323X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-11
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Big Sky - Montana
Datum konání akce
3. 3. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—