Ultra-low intensity proton beams for radiation response related experiments at the U-120M cyclotron
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F18%3A00501212" target="_blank" >RIV/61389005:_____/18:00501212 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.14311/APP.2018.14.0021" target="_blank" >http://dx.doi.org/10.14311/APP.2018.14.0021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/APP.2018.14.0021" target="_blank" >10.14311/APP.2018.14.0021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ultra-low intensity proton beams for radiation response related experiments at the U-120M cyclotron
Popis výsledku v původním jazyce
The U-120M cyclotron at the Nuclear Physics Institute (NPI) of the Czech Academy of Sciences in Rez is used for radiation hardness tests of electronics for high-energy physics experiments. These tests are usually carried out with proton fluxes of the order of 105–109 proton cm-2 s -1. Some tests done for the upgrade of the Inner Tracking System of the ALICE experiment at CERN, however, required proton beam intensities several orders of magnitude lower. This paper presents a method which has been developed to achieve the proton beam flux of the order of 1 proton cm-2 s -1. The method is mainly based on reduction of the discharge current in the cyclotron internal Penning type ion source. Influence of this new operation mode on the lifetime of ion source cathodes is discussed.
Název v anglickém jazyce
Ultra-low intensity proton beams for radiation response related experiments at the U-120M cyclotron
Popis výsledku anglicky
The U-120M cyclotron at the Nuclear Physics Institute (NPI) of the Czech Academy of Sciences in Rez is used for radiation hardness tests of electronics for high-energy physics experiments. These tests are usually carried out with proton fluxes of the order of 105–109 proton cm-2 s -1. Some tests done for the upgrade of the Inner Tracking System of the ALICE experiment at CERN, however, required proton beam intensities several orders of magnitude lower. This paper presents a method which has been developed to achieve the proton beam flux of the order of 1 proton cm-2 s -1. The method is mainly based on reduction of the discharge current in the cyclotron internal Penning type ion source. Influence of this new operation mode on the lifetime of ion source cathodes is discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Acta Polytechnica CTU Proceedings
ISBN
978-80-01-06426-9
ISSN
2336-5382
e-ISSN
—
Počet stran výsledku
6
Strana od-do
21-26
Název nakladatele
CTU Prague
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
6. 11. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—