Radiation-induced plasmid DNA damage: effect of concentration and length
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F19%3A00523903" target="_blank" >RIV/61389005:_____/19:00523903 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/19:00339326
Výsledek na webu
<a href="https://doi.org/10.1093/rpd/ncz196" target="_blank" >https://doi.org/10.1093/rpd/ncz196</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncz196" target="_blank" >10.1093/rpd/ncz196</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Radiation-induced plasmid DNA damage: effect of concentration and length
Popis výsledku v původním jazyce
Plasmid DNA is commonly used as a simpler substitute for a cell in studies of early effects of ionizing radiation because it allows to determine yields of primary DNA lesions. Experimental studies often employ plasmids of different lengths, in different concentrations in the aqueous solution. Influence of these parameters on the heavy-ion induced yields of primary DNA damage has been studied, using plasmids pUC19 (2686 bp), pBR322 (4361 bp) and pKLAC2 (9107 bp) in 10 and 50 ng/μl concentration. Results demonstrate the impact of plasmid length, while no significant difference was observed between the two concentrations. The uncertainty of the results is discussed.
Název v anglickém jazyce
Radiation-induced plasmid DNA damage: effect of concentration and length
Popis výsledku anglicky
Plasmid DNA is commonly used as a simpler substitute for a cell in studies of early effects of ionizing radiation because it allows to determine yields of primary DNA lesions. Experimental studies often employ plasmids of different lengths, in different concentrations in the aqueous solution. Influence of these parameters on the heavy-ion induced yields of primary DNA damage has been studied, using plasmids pUC19 (2686 bp), pBR322 (4361 bp) and pKLAC2 (9107 bp) in 10 and 50 ng/μl concentration. Results demonstrate the impact of plasmid length, while no significant difference was observed between the two concentrations. The uncertainty of the results is discussed.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
186
Číslo periodika v rámci svazku
2-3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
168-171
Kód UT WoS článku
000530582200005
EID výsledku v databázi Scopus
2-s2.0-85082780402