Feasibility study of a compact heavy ion source for investigation of laboratory magnetospheric plasma
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F20%3A00523771" target="_blank" >RIV/61389005:_____/20:00523771 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1063/1.5128642" target="_blank" >https://doi.org/10.1063/1.5128642</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5128642" target="_blank" >10.1063/1.5128642</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Feasibility study of a compact heavy ion source for investigation of laboratory magnetospheric plasma
Popis výsledku v původním jazyce
We are developing a laser ion source to provide a high brightness multi-charged heavy ion beam as a part of the heavy ion beam probe system, which will be used to diagnose plasma potential in the Ring Trap 1 device at the University of Tokyo. As a probe beam, Nb2+ was selected, and a detailed laser irradiation condition was explored. It was found that the laser power density of 1.2 x 10(9) W/cm(2) gives the maximum particle number of Nb2+ per laser energy from a niobium foil target. Essential ablation plasma parameters to design the laser ion source were also obtained. The expected beam current was more than 12 mA/cm(2), with a pulse width of 3.1 mu s at 200 mm away from the target.
Název v anglickém jazyce
Feasibility study of a compact heavy ion source for investigation of laboratory magnetospheric plasma
Popis výsledku anglicky
We are developing a laser ion source to provide a high brightness multi-charged heavy ion beam as a part of the heavy ion beam probe system, which will be used to diagnose plasma potential in the Ring Trap 1 device at the University of Tokyo. As a probe beam, Nb2+ was selected, and a detailed laser irradiation condition was explored. It was found that the laser power density of 1.2 x 10(9) W/cm(2) gives the maximum particle number of Nb2+ per laser energy from a niobium foil target. Essential ablation plasma parameters to design the laser ion source were also obtained. The expected beam current was more than 12 mA/cm(2), with a pulse width of 3.1 mu s at 200 mm away from the target.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
91
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
033503
Kód UT WoS článku
000521990600001
EID výsledku v databázi Scopus
2-s2.0-85082530165