An alternative neutron diffractometer performance for strain/stress measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F20%3A00534012" target="_blank" >RIV/61389005:_____/20:00534012 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1017/S0885715620000329" target="_blank" >https://doi.org/10.1017/S0885715620000329</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1017/S0885715620000329" target="_blank" >10.1017/S0885715620000329</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An alternative neutron diffractometer performance for strain/stress measurements
Popis výsledku v původním jazyce
An alternative neutron diffractometer performance, which documents the feasibility of using a high-resolution three-axis neutron diffractometer for elastic and plastic deformation studies of bulk metallic polycrystalline samples, is presented. Contrary to the conventional double-axis setting, the suggested alternative consists of an unconventional three-axis set-up employing a bent perfect crystal monochromator and an analyzer with a polycrystalline sample in between. Though the alternative is, for measurements, much more time-consuming, its sensitivity to the change of the diffraction angle of the sample is, however, substantially higher and permits also plastic deformation studies on the basis of analysis of the diffraction line profiles. Moreover, much larger widths (up to 10 mm) of the irradiated gauge volumes can be investigated when just slightly affecting the angular resolution properties of the experimental setting.
Název v anglickém jazyce
An alternative neutron diffractometer performance for strain/stress measurements
Popis výsledku anglicky
An alternative neutron diffractometer performance, which documents the feasibility of using a high-resolution three-axis neutron diffractometer for elastic and plastic deformation studies of bulk metallic polycrystalline samples, is presented. Contrary to the conventional double-axis setting, the suggested alternative consists of an unconventional three-axis set-up employing a bent perfect crystal monochromator and an analyzer with a polycrystalline sample in between. Though the alternative is, for measurements, much more time-consuming, its sensitivity to the change of the diffraction angle of the sample is, however, substantially higher and permits also plastic deformation studies on the basis of analysis of the diffraction line profiles. Moreover, much larger widths (up to 10 mm) of the irradiated gauge volumes can be investigated when just slightly affecting the angular resolution properties of the experimental setting.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Powder Diffraction
ISSN
0885-7156
e-ISSN
—
Svazek periodika
35
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
185-189
Kód UT WoS článku
000573210400006
EID výsledku v databázi Scopus
2-s2.0-85085889981