The MULTI spectrometer for measurement of beta-decay process in exotic nuclei
Popis výsledku
Identifikátory výsledku
Kód výsledku v IS VaVaI
Výsledek na webu
DOI - Digital Object Identifier
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The MULTI spectrometer for measurement of beta-decay process in exotic nuclei
Popis výsledku v původním jazyce
The construction of the portable spectrometer, MULTI, is designed for the measurement of beta-gamma-neutron coincidences on beams of radioactive exotic nuclei. It will be used in measurements of the beta-decay process of neutron-rich nuclei with large Q(beta) values accessible in radioactive beams facilities. The experimental technique includes the measurement of the ratios between gamma-ray emission and multi-neutron emission, following beta-decay of radioactive nuclei implanted into an active target. The construction of a gamma-ray spectrometer based on high-volume CeBr3+NaI(Tl) phoswich scintillation detectors is introduced. Results of the measurements of its fundamental characteristics - total detection efficiency, peak efficiency and Compton suppression effect with a Co-60 source are presented. Design of the neutron counter array, consisting of 40 proportional counters filled with He-3 gas, was optimized with Monte Carlo simulations. Results were validated with a Cf-252 spectroscopic source, leading to expected detection efficiency of similar to 35% for neutrons with energy < 1MeV. Further development plans are discussed.
Název v anglickém jazyce
The MULTI spectrometer for measurement of beta-decay process in exotic nuclei
Popis výsledku anglicky
The construction of the portable spectrometer, MULTI, is designed for the measurement of beta-gamma-neutron coincidences on beams of radioactive exotic nuclei. It will be used in measurements of the beta-decay process of neutron-rich nuclei with large Q(beta) values accessible in radioactive beams facilities. The experimental technique includes the measurement of the ratios between gamma-ray emission and multi-neutron emission, following beta-decay of radioactive nuclei implanted into an active target. The construction of a gamma-ray spectrometer based on high-volume CeBr3+NaI(Tl) phoswich scintillation detectors is introduced. Results of the measurements of its fundamental characteristics - total detection efficiency, peak efficiency and Compton suppression effect with a Co-60 source are presented. Design of the neutron counter array, consisting of 40 proportional counters filled with He-3 gas, was optimized with Monte Carlo simulations. Results were validated with a Cf-252 spectroscopic source, leading to expected detection efficiency of similar to 35% for neutrons with energy < 1MeV. Further development plans are discussed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
01003
Název nakladatele
E D P Sciences
Místo vydání
Les Ulis
Místo konání akce
Prague
Datum konání akce
21. 6. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000788459400003
Druh výsledku
D - Stať ve sborníku
OECD FORD
Nuclear physics
Rok uplatnění
2021