Popis výsledku v původním jazyce
The identification of the residual stress distribution is an important part of the analysis for the evaluation of life time of steel structures and for an estimation of their critical defect size. Stresses bring about local deformation in weld area and influence properties and behaviour of these structures during service. In this paper the results of strain/stress measurements in the vicinity of the butt weld on the spherical storage tank by neutron diffraction are presented. The storage tank was made of C-Mn unalloyed steel of the strength of ≈ 430 MPa. The specimen in the form of a plate with the dimensions of 100x145x15 mm3 (width x length x thickness). The measurements revealed maximum residual stresses on the level of 300 MPa, 150 MPa and 200 MPa in the longitudinal, transversal and normal direction, respectively.
Název v anglickém jazyce
Residual Stress Measurements in the Vicinity of the Butt Weld on the Spherical Storage Tank
Popis výsledku anglicky
The identification of the residual stress distribution is an important part of the analysis for the evaluation of life time of steel structures and for an estimation of their critical defect size. Stresses bring about local deformation in weld area and influence properties and behaviour of these structures during service. In this paper the results of strain/stress measurements in the vicinity of the butt weld on the spherical storage tank by neutron diffraction are presented. The storage tank was made of C-Mn unalloyed steel of the strength of ≈ 430 MPa. The specimen in the form of a plate with the dimensions of 100x145x15 mm3 (width x length x thickness). The measurements revealed maximum residual stresses on the level of 300 MPa, 150 MPa and 200 MPa in the longitudinal, transversal and normal direction, respectively.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
The Proceedings of the European Research Reactor Conference
ISBN
978-92-95064-36-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
European Nuclear Society
Místo vydání
Brusel
Místo konání akce
Helsinki
Datum konání akce
24. 9. 2021
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—