Neutron dose assessment in laser-generated ultra-short pulsed fields
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F23%3A00577610" target="_blank" >RIV/61389005:_____/23:00577610 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/CZ______:_____/23:N0000043
Výsledek na webu
<a href="https://doi.org/10.1093/rpd/ncac221" target="_blank" >https://doi.org/10.1093/rpd/ncac221</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac221" target="_blank" >10.1093/rpd/ncac221</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Neutron dose assessment in laser-generated ultra-short pulsed fields
Popis výsledku v původním jazyce
ELI Beamlines is one of the pillars of the Extreme Light Infrastructure European Research Infrastructure Consortium (ELI ERIC), the European project aiming at building the next generation of high power lasers for fundamental research and industrial applications. Several high-power lasers are hosted by the ELI Beamlines facility. Even at a power lower than the nominal one, when interacting with a target, the laser can generate mixed ionizing radiation fields of unique nature. One of the major laser systems, High-repetition-rate advanced petawatt laser system (HAPLS) was already used in commissioning experiments. Detecting the neutrons generated during these experiments has been a challenging task, since certain difficulties were faced. First, the experimental conditions were frequently altered during the commissioning phase (such as laser beam parameters, experimental geometry or target type). Next, the extremely short duration of the ionizing radiation pulse generated by the laser (similar to 10(-14) s) complicated the correct interpretation of the data provided by the detectors designed and calibrated in standard fields. Here, one commissioning experiment is described, together with the means of addressing the problem of the detection of the ionizing radiation and the lessons learned in this endeavour.
Název v anglickém jazyce
Neutron dose assessment in laser-generated ultra-short pulsed fields
Popis výsledku anglicky
ELI Beamlines is one of the pillars of the Extreme Light Infrastructure European Research Infrastructure Consortium (ELI ERIC), the European project aiming at building the next generation of high power lasers for fundamental research and industrial applications. Several high-power lasers are hosted by the ELI Beamlines facility. Even at a power lower than the nominal one, when interacting with a target, the laser can generate mixed ionizing radiation fields of unique nature. One of the major laser systems, High-repetition-rate advanced petawatt laser system (HAPLS) was already used in commissioning experiments. Detecting the neutrons generated during these experiments has been a challenging task, since certain difficulties were faced. First, the experimental conditions were frequently altered during the commissioning phase (such as laser beam parameters, experimental geometry or target type). Next, the extremely short duration of the ionizing radiation pulse generated by the laser (similar to 10(-14) s) complicated the correct interpretation of the data provided by the detectors designed and calibrated in standard fields. Here, one commissioning experiment is described, together with the means of addressing the problem of the detection of the ionizing radiation and the lessons learned in this endeavour.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000789" target="_blank" >EF16_019/0000789: Pokročilý výzkum s využitím fotonů a částic vytvořených vysoce intenzivními lasery</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
199
Číslo periodika v rámci svazku
15-16
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
1910-1916
Kód UT WoS článku
001082650600051
EID výsledku v databázi Scopus
2-s2.0-85175312802