Enhanced beam extraction system at the U-120M cyclotron
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F24%3A00586151" target="_blank" >RIV/61389005:_____/24:00586151 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.nima.2024.169335" target="_blank" >https://doi.org/10.1016/j.nima.2024.169335</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2024.169335" target="_blank" >10.1016/j.nima.2024.169335</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Enhanced beam extraction system at the U-120M cyclotron
Popis výsledku v původním jazyce
Since its commissioning in 1977, the U -120M cyclotron was initially equipped with a single pair of harmonic coils aimed at optimizing beam quality at lower accelerating radii. In 2022, a significant upgrade introduced a second pair of harmonic coils, positioned at a radius of approximately 50 cm, aligning with the outermost beam orbit. This addition is essential for the efficient extraction of positively accelerated ions and serves as the basis for the newly developed extraction system, which, unlike the original fully electrostatic system, consists of electrostatic deflectors and magnetic channels. This paper describes the design and installation of new harmonic coils in the accelerator vacuum chamber and presents a new extraction system using precession and linear integer resonance methods. Basic properties of these two extraction methods are given and finally, an evaluation of their advantages and limitations concerning their possible use in the cyclotron and an estimation of the efficiency of the new extraction system is made.
Název v anglickém jazyce
Enhanced beam extraction system at the U-120M cyclotron
Popis výsledku anglicky
Since its commissioning in 1977, the U -120M cyclotron was initially equipped with a single pair of harmonic coils aimed at optimizing beam quality at lower accelerating radii. In 2022, a significant upgrade introduced a second pair of harmonic coils, positioned at a radius of approximately 50 cm, aligning with the outermost beam orbit. This addition is essential for the efficient extraction of positively accelerated ions and serves as the basis for the newly developed extraction system, which, unlike the original fully electrostatic system, consists of electrostatic deflectors and magnetic channels. This paper describes the design and installation of new harmonic coils in the accelerator vacuum chamber and presents a new extraction system using precession and linear integer resonance methods. Basic properties of these two extraction methods are given and finally, an evaluation of their advantages and limitations concerning their possible use in the cyclotron and an estimation of the efficiency of the new extraction system is made.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_013%2F0001812" target="_blank" >EF16_013/0001812: Centrum urychlovačů a jaderných analytických metod - OP</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
1872-9576
Svazek periodika
1064
Číslo periodika v rámci svazku
JUL
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
169335
Kód UT WoS článku
001218017700001
EID výsledku v databázi Scopus
2-s2.0-85190949900