Poly(HEMA) brushes emerging as a new platform for direct detection of food pathogen in milk samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F11%3A00362960" target="_blank" >RIV/61389013:_____/11:00362960 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/11:10304
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.bios.2011.05.021" target="_blank" >http://dx.doi.org/10.1016/j.bios.2011.05.021</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bios.2011.05.021" target="_blank" >10.1016/j.bios.2011.05.021</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Poly(HEMA) brushes emerging as a new platform for direct detection of food pathogen in milk samples
Popis výsledku v původním jazyce
The attachment of antibodies onto poly(HEMA) brushes prepared by surface initiated ATRP provided a successful way to fabricate SPR biosensors capable of in-real time detection Cronobacter at concentrations down to 106 cells mL1 in milk. Non-specific responses to deposition of non-targeted compounds ruled out other biosensors based on poly(MeOEGMA) and poly(HOEGMA) brushes or SAMs of EG2/COEG and EG6 from detection of Cronobacter at low concentrations even if the lowest detection limit of 104 cells mL1 in PBS was reached by biosensor based on SAM of EG6. Owing to well-controlled character of ATRP it was possible to minimize the thickness of the polymer brushes films so that the fouling could be still suppressed while the capture of antigens by antibodies immobilized on the brush layer could take place close to the gold SPR surface to provide a stronger optical response.
Název v anglickém jazyce
Poly(HEMA) brushes emerging as a new platform for direct detection of food pathogen in milk samples
Popis výsledku anglicky
The attachment of antibodies onto poly(HEMA) brushes prepared by surface initiated ATRP provided a successful way to fabricate SPR biosensors capable of in-real time detection Cronobacter at concentrations down to 106 cells mL1 in milk. Non-specific responses to deposition of non-targeted compounds ruled out other biosensors based on poly(MeOEGMA) and poly(HOEGMA) brushes or SAMs of EG2/COEG and EG6 from detection of Cronobacter at low concentrations even if the lowest detection limit of 104 cells mL1 in PBS was reached by biosensor based on SAM of EG6. Owing to well-controlled character of ATRP it was possible to minimize the thickness of the polymer brushes films so that the fouling could be still suppressed while the capture of antigens by antibodies immobilized on the brush layer could take place close to the gold SPR surface to provide a stronger optical response.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosensors and Bioeletronics
ISSN
0956-5663
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
4545-4551
Kód UT WoS článku
000293104100046
EID výsledku v databázi Scopus
—