Surface tension measurement: attempt to combine pendant drop and deformed drop retraction methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F19%3A00506000" target="_blank" >RIV/61389013:_____/19:00506000 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.5109515" target="_blank" >http://dx.doi.org/10.1063/1.5109515</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5109515" target="_blank" >10.1063/1.5109515</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surface tension measurement: attempt to combine pendant drop and deformed drop retraction methods
Popis výsledku v původním jazyce
The deformed drop retraction method of boundary tension measurement is based on evaluation of ellipsoid droplet relaxation published by Luciani and Utracki. The pendant drop method is based on evaluation of equilibrium drop shape. When it is applied to viscous liquids, drop shape equilibrates during a certain time similarly as for ellipsoid droplets. This text presents an attempt to apply deformed drop retraction procedure to pendant drop in order to obtain alternative boundary tension estimate. However, the results for testing sample strongly differ from correct surface tensions. The usage of formula for ellipsoid relaxation is a weak point of the estimate presented. The challenge remaining for the future is to describe the relaxation of pendant drop.
Název v anglickém jazyce
Surface tension measurement: attempt to combine pendant drop and deformed drop retraction methods
Popis výsledku anglicky
The deformed drop retraction method of boundary tension measurement is based on evaluation of ellipsoid droplet relaxation published by Luciani and Utracki. The pendant drop method is based on evaluation of equilibrium drop shape. When it is applied to viscous liquids, drop shape equilibrates during a certain time similarly as for ellipsoid droplets. This text presents an attempt to apply deformed drop retraction procedure to pendant drop in order to obtain alternative boundary tension estimate. However, the results for testing sample strongly differ from correct surface tensions. The usage of formula for ellipsoid relaxation is a weak point of the estimate presented. The challenge remaining for the future is to describe the relaxation of pendant drop.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10404 - Polymer science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings. Volume 2107, Issue 1
ISBN
978-0-7354-1839-4
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
12
Strana od-do
1-12
Název nakladatele
American Institute of Physics
Místo vydání
Melville
Místo konání akce
Zlín
Datum konání akce
30. 7. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000479303100024