The new experiment S3 devoted to the study of reactor antineutrinos was designed and constructed as a common activity of IEAP CTU in Prague and JINR (Dubna). The S3 detector is a compact, highly segmented polystyrene-based scintillating detector composed of 80 detector elements with a gadolinium neutron converter between elements layers. A positron and a neutron are produced in an inverse beta decay initiated with an electron antineutrino in the detector. A modular multi-channel fast ADC was developed for the data acquisition for the whole 80-channel S3 detector and the 4-channel cosmic veto system. The detector meets very strict safety rules of nuclear power plants and can be installed in a chamber located immediately under the reactor. The close vicinity from the reactor enables to study neutrino properties with a higher efficiency, to investigate neutrino oscillations at short baselines and try to verify the hypothesis of a sterile neutrino. The details of the design and construction of the S3 detector, as well as properties of the modular multi-channel fast ADC system, and first tests of the device are presented.
Název v anglickém jazyce
Design and first tests of the S-3 detector of reactor antineutrinos
Popis výsledku anglicky
The new experiment S3 devoted to the study of reactor antineutrinos was designed and constructed as a common activity of IEAP CTU in Prague and JINR (Dubna). The S3 detector is a compact, highly segmented polystyrene-based scintillating detector composed of 80 detector elements with a gadolinium neutron converter between elements layers. A positron and a neutron are produced in an inverse beta decay initiated with an electron antineutrino in the detector. A modular multi-channel fast ADC was developed for the data acquisition for the whole 80-channel S3 detector and the 4-channel cosmic veto system. The detector meets very strict safety rules of nuclear power plants and can be installed in a chamber located immediately under the reactor. The close vicinity from the reactor enables to study neutrino properties with a higher efficiency, to investigate neutrino oscillations at short baselines and try to verify the hypothesis of a sterile neutrino. The details of the design and construction of the S3 detector, as well as properties of the modular multi-channel fast ADC system, and first tests of the device are presented.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10404 - Polymer science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
11011
Název nakladatele
E D P Sciences
Místo vydání
Les Ulis
Místo konání akce
Prague
Datum konání akce
21. 6. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000788459400095