Selective potentiometric detection of reactive oxygen species (ROS) in biologically relevant concentrations by a modified metalized polyporphyrine sensing layer coated with nonbiofouling poly(2-alkyl-2oxazoline)s
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F22%3A00556452" target="_blank" >RIV/61389013:_____/22:00556452 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0925400522004695?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0925400522004695?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2022.131827" target="_blank" >10.1016/j.snb.2022.131827</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Selective potentiometric detection of reactive oxygen species (ROS) in biologically relevant concentrations by a modified metalized polyporphyrine sensing layer coated with nonbiofouling poly(2-alkyl-2oxazoline)s
Popis výsledku v původním jazyce
We built a robust selective potentiometric sensor of reactive oxygen species (ROS) as a thin layer applied on the surface of smart implants, which enables the detection and localization of inflammation at an early stage. The sensor consists of a conductive polymer layer based on polythiophene with an incorporated porphyrin-metal complex that potentiometrically detects the presence of ROS. This sensor is covalently coated with a nonbiofouling layer of poly(2-methyl-2-oxazoline), which works as a biocompatibilizer but mainly prevents the sorption of proteins and other biomacromolecules naturally occurring in organisms, which could interfere with the ROS signal. We have shown that our potentiometric sensor shows a rapid response to hydrogen peroxide, does not experience interference with bovine serum albumin as a model serum protein when sensing ROS, is able to fully reversibly detect ROS with a linear response within a very wide range of biologically relevant concentrations and, most importantly, is able to distinguish between hydrogen peroxide and hypochlorite. We also performed a head-to-head comparison of two positional isomers of thienylated porphyrine for sensor applications (2TTP and 3TTP, with 3TTP shown to be more appropriate) and four different coordinated metals (Cu, Fe, Co and Mn, with Cu and especially Fe shown to be the most appropriate).
Název v anglickém jazyce
Selective potentiometric detection of reactive oxygen species (ROS) in biologically relevant concentrations by a modified metalized polyporphyrine sensing layer coated with nonbiofouling poly(2-alkyl-2oxazoline)s
Popis výsledku anglicky
We built a robust selective potentiometric sensor of reactive oxygen species (ROS) as a thin layer applied on the surface of smart implants, which enables the detection and localization of inflammation at an early stage. The sensor consists of a conductive polymer layer based on polythiophene with an incorporated porphyrin-metal complex that potentiometrically detects the presence of ROS. This sensor is covalently coated with a nonbiofouling layer of poly(2-methyl-2-oxazoline), which works as a biocompatibilizer but mainly prevents the sorption of proteins and other biomacromolecules naturally occurring in organisms, which could interfere with the ROS signal. We have shown that our potentiometric sensor shows a rapid response to hydrogen peroxide, does not experience interference with bovine serum albumin as a model serum protein when sensing ROS, is able to fully reversibly detect ROS with a linear response within a very wide range of biologically relevant concentrations and, most importantly, is able to distinguish between hydrogen peroxide and hypochlorite. We also performed a head-to-head comparison of two positional isomers of thienylated porphyrine for sensor applications (2TTP and 3TTP, with 3TTP shown to be more appropriate) and four different coordinated metals (Cu, Fe, Co and Mn, with Cu and especially Fe shown to be the most appropriate).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10404 - Polymer science
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators B - Chemical
ISSN
0925-4005
e-ISSN
0925-4005
Svazek periodika
363
Číslo periodika v rámci svazku
15 July
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
12
Strana od-do
131827
Kód UT WoS článku
000806144200005
EID výsledku v databázi Scopus
2-s2.0-85127821322