Liquid chromatography methods as a solution to inaccuracies associated with purity assessment of citric acid-based carbon dots
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F24%3A00588313" target="_blank" >RIV/61389013:_____/24:00588313 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0026265X24013523?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0026265X24013523?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2024.111240" target="_blank" >10.1016/j.microc.2024.111240</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Liquid chromatography methods as a solution to inaccuracies associated with purity assessment of citric acid-based carbon dots
Popis výsledku v původním jazyce
Herein, several analytical techniques aimed on validation of separation effectiveness of free molecular fluorophores from citric acid-based carbon dots were elaborated and compared. Generally, chromatographic methods were found more reliable than steady-state optical measurements, pointing at the LC-FLD (liquid chromatography coupled to fluorescence detector) protocols as the most sensitive. Furthermore, the applicability of the frequently reported 1H NMR technique for confirmation of the absence of highly fluorescent free low-molecular weight species in carbon dots samples was called into question. It was found that, in the case of effectively PL emitting compounds (such as 5-oxo-2,3- dihydro-5H-[1,3]thiazolo[3,2-a]pyridine-3,7-dicarboxylic acid (TPA)), the lowest concentration that could be detected with above technique (0.08 mg mL−1 of TPA) is higher than the concentration at which the particular fluorophore shows the brightest PL emission (∼0.01 mg mL−1 of TPA).
Název v anglickém jazyce
Liquid chromatography methods as a solution to inaccuracies associated with purity assessment of citric acid-based carbon dots
Popis výsledku anglicky
Herein, several analytical techniques aimed on validation of separation effectiveness of free molecular fluorophores from citric acid-based carbon dots were elaborated and compared. Generally, chromatographic methods were found more reliable than steady-state optical measurements, pointing at the LC-FLD (liquid chromatography coupled to fluorescence detector) protocols as the most sensitive. Furthermore, the applicability of the frequently reported 1H NMR technique for confirmation of the absence of highly fluorescent free low-molecular weight species in carbon dots samples was called into question. It was found that, in the case of effectively PL emitting compounds (such as 5-oxo-2,3- dihydro-5H-[1,3]thiazolo[3,2-a]pyridine-3,7-dicarboxylic acid (TPA)), the lowest concentration that could be detected with above technique (0.08 mg mL−1 of TPA) is higher than the concentration at which the particular fluorophore shows the brightest PL emission (∼0.01 mg mL−1 of TPA).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10404 - Polymer science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microchemical Journal
ISSN
0026-265X
e-ISSN
1095-9149
Svazek periodika
205
Číslo periodika v rámci svazku
October
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
9
Strana od-do
111240
Kód UT WoS článku
001280603400001
EID výsledku v databázi Scopus
2-s2.0-85199256130