Produkce peroxidu vodíku v kapilárním výboji ve vodě
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F06%3A00043412" target="_blank" >RIV/61389021:_____/06:00043412 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/06:03144000
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hydrogen peroxide production in capillary underwater discharges
Popis výsledku v původním jazyce
Hydrogen peroxide production by an AC driven capillary underwater discharge was investigated quantitatively. Concentration of formed hydrogen peroxide was measured by a colorimetric method using a specific reaction between H2O2 and a titanium reagent. Itcomes out that the amount of H2O2 increases linearly during the first hour of the discharge duration and is slightly higher at the high voltage side of the capillary. The initial rate of H2O2 formation by the capillary discharge was therefore determinedfor initial electrical conductivity of aqueous solution in the range of 100 - 500 S cm-1. The initial rate of H2O2 formation increases with applied power at fixed initial conductivity of aqueous solution. Experiments performed at fixed applied power indicate that the initial conductivity appears to have only negligible effect on the initial rate of H2O2 formation.
Název v anglickém jazyce
Hydrogen peroxide production in capillary underwater discharges
Popis výsledku anglicky
Hydrogen peroxide production by an AC driven capillary underwater discharge was investigated quantitatively. Concentration of formed hydrogen peroxide was measured by a colorimetric method using a specific reaction between H2O2 and a titanium reagent. Itcomes out that the amount of H2O2 increases linearly during the first hour of the discharge duration and is slightly higher at the high voltage side of the capillary. The initial rate of H2O2 formation by the capillary discharge was therefore determinedfor initial electrical conductivity of aqueous solution in the range of 100 - 500 S cm-1. The initial rate of H2O2 formation increases with applied power at fixed initial conductivity of aqueous solution. Experiments performed at fixed applied power indicate that the initial conductivity appears to have only negligible effect on the initial rate of H2O2 formation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/IAA1043403" target="_blank" >IAA1043403: Experimentální a teoretické studium optimalizace generace ozónu a účinnosti de-NOx procesů v nerovnovážných výbojích za atmosférického tlaku</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Czechoslovak Journal of Physics
ISSN
0011-4626
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
suppl. B
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
14
Strana od-do
1132-1139
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—