Měření faktoru zásoby stabnility pomocí Hallových senzorů na tokamaku CASTOR
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F06%3A00044140" target="_blank" >RIV/61389021:_____/06:00044140 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of Safety Factor Using Hall Probes on CASTOR Tokamak
Popis výsledku v původním jazyce
Hall sensors offer an attractive true non-inductive method of magnetic field measurements for fusion reactors. However, there is only limited experience in using of these sensors in such demanding environment. Recently, a combined magnetic probe was developed for CASTOR tokamak, which contains 3 Hall sensors and 3 coils arranged to measure all three components of magnetic field approximately in a single point of space. The probe is compatible with in-vessel use well in confinement region of CASTOR. It is fully controlled by multi-functional electronic system. Design of the system and its implementation on CASTOR is reviewed. Results obtained using this diagnostic during various regimes of operation of CASTOR tokamak are presented. Radial profile of thepoloidal magnetic field is used to deduce radial profile of safety factor.
Název v anglickém jazyce
Measurement of Safety Factor Using Hall Probes on CASTOR Tokamak
Popis výsledku anglicky
Hall sensors offer an attractive true non-inductive method of magnetic field measurements for fusion reactors. However, there is only limited experience in using of these sensors in such demanding environment. Recently, a combined magnetic probe was developed for CASTOR tokamak, which contains 3 Hall sensors and 3 coils arranged to measure all three components of magnetic field approximately in a single point of space. The probe is compatible with in-vessel use well in confinement region of CASTOR. It is fully controlled by multi-functional electronic system. Design of the system and its implementation on CASTOR is reviewed. Results obtained using this diagnostic during various regimes of operation of CASTOR tokamak are presented. Radial profile of thepoloidal magnetic field is used to deduce radial profile of safety factor.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KJB100430504" target="_blank" >KJB100430504: Měření magnetických polí na zařízeních pro výzkum termonuklární fůze pomocí Hallových detektorů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Czechoslovak Journal of Physics
ISSN
0011-4626
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
suppl.B
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
14
Strana od-do
104-110