Čtyř-segmentová vakuová XUV fotodioda
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F07%3A00095510" target="_blank" >RIV/61389021:_____/07:00095510 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Four-segment soft X-ray vacuum photodiode
Popis výsledku v původním jazyce
A soft X-ray/XUV diode (XRD) is a powerful diagnostic tool for system alignment, among others, in capillary discharge experiments, which generate directional soft x-ray radiation, eventually a laser pulse. In our experimental devices (CAPEX and CAPEX-U)we usually used PIN diode or vacuum photodiode (one-segment). These diagnostics are not very suitable, mainly because many shots (more than 50) are necessary to find the optical axis. During last year we have designed and manufactured a four-segment softX-ray vacuum diode with a golden photocathode, which detects the soft X-ray radiation emitted in the axial direction. This new diagnostic tool is capable to locate the axis of soft X-ray laser in a few capillary shots (less than 10). The description andthe experimental measurement of the four-segment soft X-ray vacuum diode are a subject of this paper.
Název v anglickém jazyce
Four-segment soft X-ray vacuum photodiode
Popis výsledku anglicky
A soft X-ray/XUV diode (XRD) is a powerful diagnostic tool for system alignment, among others, in capillary discharge experiments, which generate directional soft x-ray radiation, eventually a laser pulse. In our experimental devices (CAPEX and CAPEX-U)we usually used PIN diode or vacuum photodiode (one-segment). These diagnostics are not very suitable, mainly because many shots (more than 50) are necessary to find the optical axis. During last year we have designed and manufactured a four-segment softX-ray vacuum diode with a golden photocathode, which detects the soft X-ray radiation emitted in the axial direction. This new diagnostic tool is capable to locate the axis of soft X-ray laser in a few capillary shots (less than 10). The description andthe experimental measurement of the four-segment soft X-ray vacuum diode are a subject of this paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of ICPIG?07
ISBN
978-80-87026-01-4
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1276-1278
Název nakladatele
Institute of Plasma Physics AS CR,v.v
Místo vydání
Praha
Místo konání akce
Prague
Datum konání akce
15. 7. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—